1-800-561-8187

information@ITM.com

Chat Live

Customer Reviews

Fluke Ti95 9hz FCA Fluke Connect Kit

Model: TI95 9HZ/FCA | Order No: TI95-9HZ/FCA | UPC: 095969724845

Fluke Ti95 9hz FCA Fluke Connect Kit-


Downloads: datasheet

Fluke Ti95 9hz FCA Fluke Connect Kit

Model: TI95 9HZ/FCA | Order No: TI95-9HZ/FCA

Fluke Connect Kit with the 3000-FC Digital Multimeter and a3001FC iFlex AC Current Module.

Fluke Connect Kit with the 3000-FC Digital Multimeter and a3001FC iFlex AC Current Module.

This product has been discontinued. Click here for the replacement model(s).


Fluke TI95-9HZ/FCA Offers

Features

  • Get up to 84% better spatial resolution for superior image quality
  • View images on 16% larger screen - the largest LCD in its class
  • Communicate back to your supervisors with your smart phone without having to leave the site with the Fluke Connect app and save more time and trouble than before when trying to solve problems and identifying next steps
  • Designed for easy, one-hand operation
  • Built Fluke tough durable enough to handle a 2-meter drop, and IP54-rated

Fluke Ti95 Specifications

Detailed Specifications
IR resolution (FPA size) 80 x 80 FPA Uncooled Microbolometer
Spectral band 9 µm to 15 µm (long wave)
Capture or refresh rate 9 Hz
NETD (thermal sensitivity) ≤0.10 °C at 30 °C target temp (100 mK)
FOV (field of view) 26 °H x 26 °V
IFOV (spatial resolution) 5.6 mRad
Temperature measurement range (not calibrated below -10 °C) -20 °C to + 250 °C (-4 °F to 482 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism Fixed focus 46 cm (18in) and beyond
IR Fusion® technology PIP (46 cm (18in)), full IR, full visible
CNX wireless enabled No
Color alarms No
Standard palettes Ironbow, Blue-Red, High-Contrast, Amber, Hot Metal, Grayscale
Ultra Contrast™ palettes -
Hot/cold markers -
User definable spot markers No
Centerpoint Yes
Centerbox (MIN/AVG/MAX) Fixed-size measurement box
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 122 cm (48 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
IR-PhotoNotes™ annotation system No
Laser pointer No
Torch No
Emissivity correction Yes
Transmission correction No
Background (reflected) compensation Yes
Voice annotation (audio) No
Multi-mode video output -
Multi-mode video recording (standard AVI with MPEG encoding) -
Multi-mode video recording (radiometric .IS3) -
Memory review Thumbnail review
Battery (field-replaceable, rechargeable) One
Battery life 4+ hours (each)*
External battery charging base Optional (accessory)
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Recommended calibration cycle Two-years
Multifunction card reader -
Memory storage 2 GB SD memory card
Direct download capability Mini USB download direct to PC
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes
*Assumes 50% brightness of LCD

Fluke 3000FC Specifications

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

AC voltage

Accuracy 2,3,4
Range1 Resolution 45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V

1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of < 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.

DC voltage, continuity, resistance, diode test and capacitance

Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
Ω 600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5% + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF1 1 µF 10 % typical

1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.

AC and DC Current

Function Range1 Resolution Accuracy
mA AC (45 Hz to 1 kHZ) 60.00 mA 0.01 mA 1.5 % + 3
400.0 mA3 0.1 mA
mA DC2 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA3 0.1 mA

1 All ac current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

Frequency

Range Resolution Accuracy [1]
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz

1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

MIN/MAX Recording

Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.

General specifications (Not compatible with Fluke CNX test tools)

Maximum voltage between any terminal and earth ground 1000 V dc or ac rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)

Fluke A3001-FC Specifications

Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3 % ± 5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
LCD w/backlight 3.5 digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature coefficient Add 0.1 X (specified accuracy)/ °C (>18 °C or <28 °C)
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution degree 2
Jaw opening 25.4 cm (10 in) coil
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Click here for complete specifications on the Fluke TI95 9HZ/FCA

What's included with the Fluke TI95 9HZ/FCA

  • Fluke Ti95 9hz FCA Fluke Connect Kit
  • This product features Fluke Connect Technology

    See it. Save it. Share it. All the facts, right in the field.

    Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

    Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

    Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


    Fluke Connect Features:

    • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
    • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
    • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
    • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
    • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

    Fluke Connect Benefits:

    • Maximize uptime
    • Minimize maintenance costs
    • Better assessments with accurate records
    • Higher efficiency with less walking around; no notebook and excel needed
    • Share troubleshooting knowledge live
    • Create and share helpful content in the field
    • Access to Fluke digital product manuals means no need to carry manuals in the field
    • Keep organized manually entered measurements

    Click on a category to view a selection of compatible accessories with the Fluke Ti95 9hz FCA Fluke Connect Kit.

    Fluke CV200 ClirVu 50 mm (2 in) Infrared Window, Hand Turn CV200
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke FLK-100-CLKT C-Range IR Window 4" (100mm) FLK-100-CLKT
    C-Range IR Window for Outdoor and Indoor Applications, 4" (100m) with KWIK Twist.




    Fluke CV300 ClirVu 75 mm (3 in) Infrared Window, Hand Turn CV300
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV400 ClirVu 95 mm (4 in) Infrared Window, Hand Turn CV400
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV401 ClirVu 95 mm (4 in) Infrared Window, Security Key CV401
    Increase the safety and speed of your electrical thermal imaging inspection with the new Fluke CV Series of ClirVu infrared windows.




    Fluke FLK-075-CLKT C-Range IR Window 3" (75mm) FLK-075-CLKT
    3" (75mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-050-CLKT C-Range IR Window 2" (50mm) FLK-050-CLKT
    2" (50mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke BOOK-ITP Introduction to Thermography Principles Book BOOK-ITP
    Provides an overview of the latest information on the safe, efficient, and practical use of thermal imagers. Full-color, soft-cover book that depicts and describes many thermal images of electrical, electro-mechanical, HVAC/R, process, and building inspection applications with real-world examples illustrate commercial, industrial, municipal, and residential environments and applications.




    Fluke TI-SBP3 Spare Battery Pack TI-SBP3
    Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.




    Fluke TI-SBC3B Smart Battery Charger TI-SBC3B
    Charging base for rechargeable lithium-ion battery packs.








    Fluke A3000 FC Kit A3000 FC Kit
    Includes the A3000 FC Wireless Current Clamp Meter and Fluke 3000 FC Multimeter with Fluke Connect wireless functionality.




    Fluke A3001 FC Wireless iFlex AC Current Module A3001FC
    The A3001 FC Wireless iFlex AC Current Module that wirelessly relays measurements to any Fluke Connect system.




    Fluke A3002 FC Wireless AC/DC Current Module A3002FC
    Wirelessly receives and pass measurements from the i410 or i1010 AC/DC clamps accessories and other Fluke Connect™ enabled master units with this wireless AC/C current module.




    Fluke V3000 FC Wireless True-rms AC Voltage Module V3000FC
    The V3000 FC Wireless Voltage Module measures true-rms AC voltage and relays measurements to any Fluke Connect master units




    Fluke V3001 FC Wireless DC Voltage Module V3001FC
    The V3001 FC Wireless Voltage Module measures DC voltage and relays measurements to any Fluke Connect master units




    Fluke T3000 FC Wireless K-Type Temperature Module T3000-FC
    Share test data through the Fluke Connect app when you pair this k-type temperature module with any other Fluke Connect remote modules. This allows you to access live readings without being exposed to the live panel. Additionally, you can identify temperature differences between the three phases.




    Fluke Connect 3000FC Wireless Digital Multimeter 3000FC
    Part of the Fluke Connect team of wireless tools, capable of communicating with up to three modules at one time. Features a measurement range from 0.5A to 400A.




    Customer Reviews for the Fluke TI95 9HZ/FCA

    Ask a question about Fluke Ti95 9hz FCA Fluke Connect Kit

    Fluke TI95-9HZ/FCA Offers

    Features

    • Get up to 84% better spatial resolution for superior image quality
    • View images on 16% larger screen - the largest LCD in its class
    • Communicate back to your supervisors with your smart phone without having to leave the site with the Fluke Connect app and save more time and trouble than before when trying to solve problems and identifying next steps
    • Designed for easy, one-hand operation
    • Built Fluke tough durable enough to handle a 2-meter drop, and IP54-rated

    Fluke Ti95 Specifications

    Detailed Specifications
    IR resolution (FPA size) 80 x 80 FPA Uncooled Microbolometer
    Spectral band 9 µm to 15 µm (long wave)
    Capture or refresh rate 9 Hz
    NETD (thermal sensitivity) ≤0.10 °C at 30 °C target temp (100 mK)
    FOV (field of view) 26 °H x 26 °V
    IFOV (spatial resolution) 5.6 mRad
    Temperature measurement range (not calibrated below -10 °C) -20 °C to + 250 °C (-4 °F to 482 °F)
    Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
    Focus mechanism Fixed focus 46 cm (18in) and beyond
    IR Fusion® technology PIP (46 cm (18in)), full IR, full visible
    CNX wireless enabled No
    Color alarms No
    Standard palettes Ironbow, Blue-Red, High-Contrast, Amber, Hot Metal, Grayscale
    Ultra Contrast™ palettes -
    Hot/cold markers -
    User definable spot markers No
    Centerpoint Yes
    Centerbox (MIN/AVG/MAX) Fixed-size measurement box
    Level and span control Manual and auto
    Minimum span in auto mode 5 °C
    Minimum span in manual mode 2.5 °C
    Minimum IR focus distance 122 cm (48 in)
    Weight 0.726 kg (1.6 lb)
    Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
    LCD display 3.5 inch diagonal (portrait format)
    Visible camera 2 megapixel industrial-grade
    IR-PhotoNotes™ annotation system No
    Laser pointer No
    Torch No
    Emissivity correction Yes
    Transmission correction No
    Background (reflected) compensation Yes
    Voice annotation (audio) No
    Multi-mode video output -
    Multi-mode video recording (standard AVI with MPEG encoding) -
    Multi-mode video recording (radiometric .IS3) -
    Memory review Thumbnail review
    Battery (field-replaceable, rechargeable) One
    Battery life 4+ hours (each)*
    External battery charging base Optional (accessory)
    Charging power supply Yes
    Drop test 2 meter (6.5 feet)
    Ingress protection (IP) rating (IEC 60529) IP 54
    Recommended calibration cycle Two-years
    Multifunction card reader -
    Memory storage 2 GB SD memory card
    Direct download capability Mini USB download direct to PC
    Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
    Operating humidity Operating and storage 10 % to 95 %, non-condensing
    Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
    Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
    C Tick IEC/EN 61326-1
    EMI, RFI, EMC EN61326-1; FCC Part 5
    User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
    Standard warranty period Two-years
    Extended warranty and service plans Yes
    *Assumes 50% brightness of LCD

    Fluke 3000FC Specifications

    For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

    AC voltage

    Accuracy 2,3,4
    Range1 Resolution 45 Hz to 500 Hz 500 Hz to 1 kHz
    600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
    6.000 V 0.001 V
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V

    1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
    2 Crest factor of < 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    4 Do not exceed 107 V-Hz.

    DC voltage, continuity, resistance, diode test and capacitance

    Function Range Resolution Accuracy
    mV 600.0 mV 0.1 mV 0.09 % + 2
    V 6.000 V 0.001 V 0.09 % + 2
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V 0.15 % + 2
    Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
    Ω 600.0 Ω 0.1 Ω 0.5 % + 2
    6.000 kΩ 0.001 kΩ 0.5% + 1
    60.00 kΩ 0.01 kΩ
    60.00 kΩ 0.1 kΩ
    600.0 kΩ 0.001 MΩ
    50.00 MΩ 0.01 MΩ 1.5 % + 3
    Diode test 2.000 V 0.001 V 1 % + 2
    µF 1000 nF 1 nF 1.2 % + 2
    10.00 µF 0.01 µF
    100.0 µF 0.1 µF
    9999 µF1 1 µF 10 % typical

    1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.

    AC and DC Current

    Function Range1 Resolution Accuracy
    mA AC (45 Hz to 1 kHZ) 60.00 mA 0.01 mA 1.5 % + 3
    400.0 mA3 0.1 mA
    mA DC2 60.00 mA 0.01 mA 0.5 % + 3
    400.0 mA3 0.1 mA

    1 All ac current ranges are specified from 5 % of range to 100 % of range.
    2 Input burden voltage (typical): 400 mA input 2 mV/mA.
    3 400.0 mA accuracy specified up to 600 mA overload.

    Frequency

    Range Resolution Accuracy [1]
    99.99 Hz 0.01 Hz 0.1 % + 1
    999.9 Hz 0.1 Hz
    9.999 kHz 0.001 kHz
    99.99 kHz 0.01 kHz

    1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

    MIN/MAX Recording

    Function Accuracy
    DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
    AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.

    General specifications (Not compatible with Fluke CNX test tools)

    Maximum voltage between any terminal and earth ground 1000 V dc or ac rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate: 4/sec
    Votls, amps, ohms: 6000 counts
    Frequency: 10,000 counts
    Capacitance: 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed: Up to 20m
    Obstructed, sheetrock wall: Up to 6.5m
    Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
    Temperature Operating: -10 °C to 50 °C
    Storage: -40 °C to 60 °C
    Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
    Weight 340 g (12 oz)

    Fluke A3001-FC Specifications

    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3 % ± 5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
    LCD w/backlight 3.5 digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed: Up to 20 m
    Obstructed, sheetrock wall: Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Temperature coefficient Add 0.1 X (specified accuracy)/ °C (>18 °C or <28 °C)
    Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution Degree 2
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    Click here for complete specifications on the Fluke TI95 9HZ/FCA

    What's included with the Fluke TI95 9HZ/FCA

  • Fluke Ti95 9hz FCA Fluke Connect Kit
  • This product features Fluke Connect Technology

    See it. Save it. Share it. All the facts, right in the field.

    Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

    Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

    Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


    Fluke Connect Features:

    • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
    • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
    • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
    • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
    • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

    Fluke Connect Benefits:

    • Maximize uptime
    • Minimize maintenance costs
    • Better assessments with accurate records
    • Higher efficiency with less walking around; no notebook and excel needed
    • Share troubleshooting knowledge live
    • Create and share helpful content in the field
    • Access to Fluke digital product manuals means no need to carry manuals in the field
    • Keep organized manually entered measurements

    Click on a category to view a selection of compatible accessories with the Fluke Ti95 9hz FCA Fluke Connect Kit.

    Fluke CV200 ClirVu 50 mm (2 in) Infrared Window, Hand Turn CV200
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke FLK-100-CLKT C-Range IR Window 4" (100mm) FLK-100-CLKT
    C-Range IR Window for Outdoor and Indoor Applications, 4" (100m) with KWIK Twist.




    Fluke CV300 ClirVu 75 mm (3 in) Infrared Window, Hand Turn CV300
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV400 ClirVu 95 mm (4 in) Infrared Window, Hand Turn CV400
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV401 ClirVu 95 mm (4 in) Infrared Window, Security Key CV401
    Increase the safety and speed of your electrical thermal imaging inspection with the new Fluke CV Series of ClirVu infrared windows.




    Fluke FLK-075-CLKT C-Range IR Window 3" (75mm) FLK-075-CLKT
    3" (75mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-050-CLKT C-Range IR Window 2" (50mm) FLK-050-CLKT
    2" (50mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke BOOK-ITP Introduction to Thermography Principles Book BOOK-ITP
    Provides an overview of the latest information on the safe, efficient, and practical use of thermal imagers. Full-color, soft-cover book that depicts and describes many thermal images of electrical, electro-mechanical, HVAC/R, process, and building inspection applications with real-world examples illustrate commercial, industrial, municipal, and residential environments and applications.




    Fluke TI-SBP3 Spare Battery Pack TI-SBP3
    Extra battery pack for Ti400, Ti300, Ti200, Ti125, Ti110, Ti105, Ti100, Ti95, Ti90, TiR125, TiR110, TiR105, Ti32, Ti29, Ti27, and TiS Infrared Cameras.




    Fluke TI-SBC3B Smart Battery Charger TI-SBC3B
    Charging base for rechargeable lithium-ion battery packs.








    Fluke A3000 FC Kit A3000 FC Kit
    Includes the A3000 FC Wireless Current Clamp Meter and Fluke 3000 FC Multimeter with Fluke Connect wireless functionality.




    Fluke A3001 FC Wireless iFlex AC Current Module A3001FC
    The A3001 FC Wireless iFlex AC Current Module that wirelessly relays measurements to any Fluke Connect system.




    Fluke A3002 FC Wireless AC/DC Current Module A3002FC
    Wirelessly receives and pass measurements from the i410 or i1010 AC/DC clamps accessories and other Fluke Connect™ enabled master units with this wireless AC/C current module.




    Fluke V3000 FC Wireless True-rms AC Voltage Module V3000FC
    The V3000 FC Wireless Voltage Module measures true-rms AC voltage and relays measurements to any Fluke Connect master units




    Fluke V3001 FC Wireless DC Voltage Module V3001FC
    The V3001 FC Wireless Voltage Module measures DC voltage and relays measurements to any Fluke Connect master units




    Fluke T3000 FC Wireless K-Type Temperature Module T3000-FC
    Share test data through the Fluke Connect app when you pair this k-type temperature module with any other Fluke Connect remote modules. This allows you to access live readings without being exposed to the live panel. Additionally, you can identify temperature differences between the three phases.




    Fluke Connect 3000FC Wireless Digital Multimeter 3000FC
    Part of the Fluke Connect team of wireless tools, capable of communicating with up to three modules at one time. Features a measurement range from 0.5A to 400A.




    Ask a question about Fluke Ti95 9hz FCA Fluke Connect Kit

    Customer Reviews for the Fluke TI95 9HZ/FCA

    More Fluke Products


    Fluke Connect is the best way to stay in contact with your team without leaving the field.