1-800-561-8187

information@ITM.com

Chat Live

Customer Reviews

Fluke Ti300 60hz FCA Fluke Connect Kit

Model: TI300 60HZ/FCA | Order No: TI300-60HZ/FCA | UPC: 095969724869

Fluke Ti300 60hz FCA Fluke Connect Kit-


Downloads: datasheet

Fluke Ti300 60hz FCA Fluke Connect Kit

Model: TI300 60HZ/FCA | Order No: TI300-60HZ/FCA

This kit includes the Ti300 60Hz camera, the Fluke 3000 FC digital multimeter and the a3001FC iFlex AC Current Module.

This kit includes the Ti300 60Hz camera, the Fluke 3000 FC digital multimeter and the a3001FC iFlex AC Current Module.

This product has been discontinued. Click here for the replacement model(s).


Fluke TI300-60HZ/FCA Offers

Ti300-60hz Features

  • LaserSharp® Auto Focus - get consistently in-focus images. Every. Single. Time. Utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements you need. Troubleshooting has never been easier.
  • Fluke Connect™ App - See It. Save It. Share It. All the facts, right in the field
  • Capture additional digital images to show location or additional site details with IR-PhotoNotes™ Annotation System

3000-FC Features

  • Wireless technology allows connectivity between your phone, PC, and all Fluke Connect enabled test tools
  • Let your team see what you see in an instant with ShareLive™ video call
  • Save money and time by taking multiple measurements simultaneously

A3001-FC Features

  • Measure up to 2500A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings

Fluke Ti200 / 300 / 400 Specifications

Fluke Ti400 Fluke Ti300 Fluke Ti200
Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F) -20 °C to +650 °C (-4 °F to +1202 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (by number and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type Focal Plane Array, uncooled microbolometer, 320 x 240 pixels Focal Plane Array, uncooled microbolometer, 240 X 180 pixels Focal Plane Array, uncooled microbolometer, 200 X 150 pixels
Thermal sensitivity (NETD) < 0.05 °C at 30 °C target temp (50 mK) < 0.075 °C at 30 °C target temp (75 mK)
Total pixels 76,800 43,200 30,000
Infrared spectral band 7.5 ?m to 14 ?m (long wave)
Visual (visible light) camera Industrial performance 5.0 megapixel
Standard infrared lens type
Field of view 24 ° x 17 °
Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad
Minimum focus distance 15 cm (approx. 6 in)
Optional telephoto infrared lens type
Field of view 12 ° x 9 °
Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad
Minimum focus distance 45 cm (approx. 18 in)
Optional wide-angle infrared lens type
Field of view 46 ° x 34 °
Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad
Minimum focus distance 15 cm (approx. 6 in)
Focus mechanism
LaserSharp™ Auto Focus System Yes
Advanced Manual Focus Yes
Image presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
IR-Fusion® information
Picture-In-Picture (PIP) Yes
Full screen infrared Yes
AutoBlend™ mode Yes
Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
Image capture and data storage
Image capture, review, save mechanism One-handed image capture, review, and save capability
Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Thumbnail view navigation and review selection
Other time-saving and productivity features
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes™ Yes
Wi-Fi connectivity Yes, to PC, iPhone® , iPad® and WiFi to LAN*
Text annotation* Yes
Video recording* Standard and Radiometric
Streaming Video Via USB to PC and HDMI to HDMI compatible screen
Cardinal Compass* Yes*
Auto capture (temperature and interval)* Yes*
Remote control and operation (for special and advanced applications) Yes No No
General Specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image
Expandable-contractable Measurement Box with MIN-AVG-MAX temp
Color alarms
User selectable backlight setting
Graphical information display preference
Software SmartView® and SmartView Mobile App - full analysis and reporting software included
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power saving User selectable sleep and power off modes
Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Subpart B Class B
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
Weight (battery included) 1.04 Kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

Fluke 3000FC Specifications

For all Specifications accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

AC voltage

Accuracy 2,3,4
Range1 Resolution 45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V

1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of < 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.

DC voltage, continuity, resistance, diode test and capacitance

Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
Ω 600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5% + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF1 1 µF 10 % typical

1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.

AC and DC current

Function Range1 Resolution Accuracy
mA AC (45 Hz to 1 kHZ) 60.00 mA 0.01 mA 1.5 % + 3
400.0 mA3 0.1 mA
mA DC2 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA3 0.1 mA

1 All ac current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

Frequency

Range Resolution Accuracy [1]
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz

1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

MIN/MAX Recording

Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.

General specifications (Not compatible with Fluke CNX test tools)

Maximum voltage between any terminal and earth ground 1000 V dc or ac rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)

Fluke A3001-FC Specifications

Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3 % ± 5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
LCD w/backlight 3.5 digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Temperature coefficient Add 0.1 X (specified accuracy)/ °C (>18 °C or <28 °C)
Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
Altitude Operating: 2,000 m
Storage: 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution Degree 2
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution degree 2
Jaw opening 25.4 cm (10 in) coil
Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Click here for complete specifications on the Fluke TI300 60HZ/FCA

What's included with the Fluke TI300 60HZ/FCA

  • Fluke Ti300 60hz FCA Fluke Connect Kit
  • This product features Fluke Connect Technology

    See it. Save it. Share it. All the facts, right in the field.

    Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

    Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

    Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


    Fluke Connect Features:

    • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
    • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
    • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
    • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
    • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

    Fluke Connect Benefits:

    • Maximize uptime
    • Minimize maintenance costs
    • Better assessments with accurate records
    • Higher efficiency with less walking around; no notebook and excel needed
    • Share troubleshooting knowledge live
    • Create and share helpful content in the field
    • Access to Fluke digital product manuals means no need to carry manuals in the field
    • Keep organized manually entered measurements

    Click on a category to view a selection of compatible accessories with the Fluke Ti300 60hz FCA Fluke Connect Kit.

    Fluke LENS/25MAC2 Optional Thermal Imaging Lens, 25 µm Macro LENS/25MAC2
    Optional macro lens for the TI200/300/400 thermal imaging cameras.




    Fluke LENS/4XTELE2 Optional Thermal Imaging Lens, 4x Telephoto LENS/4XTELE2
    Optional 4X Telephoto Lens for the TI200/300/400 Thermal Imaging Cameras.




    Fluke FLK-050-CLKT C-Range IR Window 2" (50mm) FLK-050-CLKT
    2" (50mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-075-CLKT C-Range IR Window 3" (75mm) FLK-075-CLKT
    3" (75mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-100-CLKT C-Range IR Window 4" (100mm) FLK-100-CLKT
    C-Range IR Window for Outdoor and Indoor Applications, 4" (100m) with KWIK Twist.




    Fluke CV200 ClirVu 50 mm (2 in) Infrared Window, Hand Turn CV200
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV401 ClirVu 95 mm (4 in) Infrared Window, Security Key CV401
    Increase the safety and speed of your electrical thermal imaging inspection with the new Fluke CV Series of ClirVu infrared windows.




    Fluke CV400 ClirVu 95 mm (4 in) Infrared Window, Hand Turn CV400
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV300 ClirVu 75 mm (3 in) Infrared Window, Hand Turn CV300
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Customer Reviews for the Fluke TI300 60HZ/FCA

    Ask a question about Fluke Ti300 60hz FCA Fluke Connect Kit

    Fluke TI300-60HZ/FCA Offers

    Ti300-60hz Features

    • LaserSharp® Auto Focus - get consistently in-focus images. Every. Single. Time. Utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements you need. Troubleshooting has never been easier.
    • Fluke Connect™ App - See It. Save It. Share It. All the facts, right in the field
    • Capture additional digital images to show location or additional site details with IR-PhotoNotes™ Annotation System

    3000-FC Features

    • Wireless technology allows connectivity between your phone, PC, and all Fluke Connect enabled test tools
    • Let your team see what you see in an instant with ShareLive™ video call
    • Save money and time by taking multiple measurements simultaneously

    A3001-FC Features

    • Measure up to 2500A AC
    • Use as a standalone meter or as part of the system
    • Logging function for recording and saving up to 65,000 readings

    Fluke Ti200 / 300 / 400 Specifications

    Fluke Ti400 Fluke Ti300 Fluke Ti200
    Temperature
    Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F) -20 °C to +650 °C (-4 °F to +1202 °F)
    Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
    On-screen emissivity correction Yes (by number and table)
    On-screen reflected background temperature compensation Yes
    On-screen transmission correction Yes
    Imaging performance
    Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
    Detector type Focal Plane Array, uncooled microbolometer, 320 x 240 pixels Focal Plane Array, uncooled microbolometer, 240 X 180 pixels Focal Plane Array, uncooled microbolometer, 200 X 150 pixels
    Thermal sensitivity (NETD) < 0.05 °C at 30 °C target temp (50 mK) < 0.075 °C at 30 °C target temp (75 mK)
    Total pixels 76,800 43,200 30,000
    Infrared spectral band 7.5 ?m to 14 ?m (long wave)
    Visual (visible light) camera Industrial performance 5.0 megapixel
    Standard infrared lens type
    Field of view 24 ° x 17 °
    Spatial resolution (IFOV) 1.31 mRad 1.75 mRad 2.09 mRad
    Minimum focus distance 15 cm (approx. 6 in)
    Optional telephoto infrared lens type
    Field of view 12 ° x 9 °
    Spatial resolution (IFOV) 0.65 mRad 0.87 mRad 1.05 mRad
    Minimum focus distance 45 cm (approx. 18 in)
    Optional wide-angle infrared lens type
    Field of view 46 ° x 34 °
    Spatial resolution (IFOV) 2.62 mRad 3.49 mRad 4.19 mRad
    Minimum focus distance 15 cm (approx. 6 in)
    Focus mechanism
    LaserSharp™ Auto Focus System Yes
    Advanced Manual Focus Yes
    Image presentation
    Palettes
    Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
    Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
    Level and span Smooth auto-scaling and manual scaling of level and span
    Fast auto toggle between manual and auto modes Yes
    Fast auto-rescale in manual mode Yes
    Minimum span (in manual mode) 2.0 °C (3.6 °F)
    Minimum span (in auto mode) 3.0 °C (5.4 °F)
    IR-Fusion® information
    Picture-In-Picture (PIP) Yes
    Full screen infrared Yes
    AutoBlend™ mode Yes
    Color alarms (temperature alarms) High-temperature , low-temperature, and isotherm (user-selectable)
    Image capture and data storage
    Image capture, review, save mechanism One-handed image capture, review, and save capability
    Storage medium Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
    File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
    No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files
    Export file formats w/SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
    Memory review Thumbnail view navigation and review selection
    Other time-saving and productivity features
    Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
    IR-PhotoNotes™ Yes
    Wi-Fi connectivity Yes, to PC, iPhone® , iPad® and WiFi to LAN*
    Text annotation* Yes
    Video recording* Standard and Radiometric
    Streaming Video Via USB to PC and HDMI to HDMI compatible screen
    Cardinal Compass* Yes*
    Auto capture (temperature and interval)* Yes*
    Remote control and operation (for special and advanced applications) Yes No No
    General Specifications
    Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
    Relative humidity 10 % to 95 % non-condensing
    Ruggedized Touchscreen Display (Capacitive) 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
    Controls and adjustments User selectable temperature scale (°C/°F)
    Language selection
    Time/Date set
    Emissivity selection
    Reflected background temperature compensation
    Transmission correction
    User selectable hot spot and cold spot, and center point on the image
    Expandable-contractable Measurement Box with MIN-AVG-MAX temp
    Color alarms
    User selectable backlight setting
    Graphical information display preference
    Software SmartView® and SmartView Mobile App - full analysis and reporting software included
    Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
    Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
    Battery charge time 2.5 hours to full charge
    AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models
    AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
    Power saving User selectable sleep and power off modes
    Safety standards UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
    Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
    C Tick IEC/EN 61326-1
    US FCC CFR 47, Part 15 Subpart B Class B
    Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
    Shock 25 g, IEC 68-2-29
    Drop Engineered to withstand 2 meter (6.5 feet) with standard lens
    Size (H x W x L) 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in)
    Weight (battery included) 1.04 Kg (2.3 lb)
    Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
    Warranty Two-years (standard), extended warranties are available
    Recommended calibration cycle Two-years (assumes normal operation and normal aging)
    Supported Languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

    Fluke 3000FC Specifications

    For all Specifications accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

    AC voltage

    Accuracy 2,3,4
    Range1 Resolution 45 Hz to 500 Hz 500 Hz to 1 kHz
    600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
    6.000 V 0.001 V
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V

    1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
    2 Crest factor of < 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
    4 Do not exceed 107 V-Hz.

    DC voltage, continuity, resistance, diode test and capacitance

    Function Range Resolution Accuracy
    mV 600.0 mV 0.1 mV 0.09 % + 2
    V 6.000 V 0.001 V 0.09 % + 2
    60.00 V 0.01 V
    600.0 V 0.1 V
    1000 V 1 V 0.15 % + 2
    Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
    Ω 600.0 Ω 0.1 Ω 0.5 % + 2
    6.000 kΩ 0.001 kΩ 0.5% + 1
    60.00 kΩ 0.01 kΩ
    60.00 kΩ 0.1 kΩ
    600.0 kΩ 0.001 MΩ
    50.00 MΩ 0.01 MΩ 1.5 % + 3
    Diode test 2.000 V 0.001 V 1 % + 2
    µF 1000 nF 1 nF 1.2 % + 2
    10.00 µF 0.01 µF
    100.0 µF 0.1 µF
    9999 µF1 1 µF 10 % typical

    1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.

    AC and DC current

    Function Range1 Resolution Accuracy
    mA AC (45 Hz to 1 kHZ) 60.00 mA 0.01 mA 1.5 % + 3
    400.0 mA3 0.1 mA
    mA DC2 60.00 mA 0.01 mA 0.5 % + 3
    400.0 mA3 0.1 mA

    1 All ac current ranges are specified from 5 % of range to 100 % of range.
    2 Input burden voltage (typical): 400 mA input 2 mV/mA.
    3 400.0 mA accuracy specified up to 600 mA overload.

    Frequency

    Range Resolution Accuracy [1]
    99.99 Hz 0.01 Hz 0.1 % + 1
    999.9 Hz 0.1 Hz
    9.999 kHz 0.001 kHz
    99.99 kHz 0.01 kHz

    1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

    MIN/MAX Recording

    Function Accuracy
    DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
    AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.

    General specifications (Not compatible with Fluke CNX test tools)

    Maximum voltage between any terminal and earth ground 1000 V dc or ac rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate: 4/sec
    Votls, amps, ohms: 6000 counts
    Frequency: 10,000 counts
    Capacitance: 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed: Up to 20m
    Obstructed, sheetrock wall: Up to 6.5m
    Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
    Temperature Operating: -10 °C to 50 °C
    Storage: -40 °C to 60 °C
    Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
    Relative humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
    Weight 340 g (12 oz)

    Fluke A3001-FC Specifications

    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3 % ± 5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
    LCD w/backlight 3.5 digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed: Up to 20 m
    Obstructed, sheetrock wall: Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
    Operating temperature -10 °C to +50 °C
    Storage temperature -40 °C to +60 °C
    Temperature coefficient Add 0.1 X (specified accuracy)/ °C (>18 °C or <28 °C)
    Operating humidity 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution Degree 2
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (HxWxD) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
    Weight .22 kg (8 oz)
    Click here for complete specifications on the Fluke TI300 60HZ/FCA

    What's included with the Fluke TI300 60HZ/FCA

  • Fluke Ti300 60hz FCA Fluke Connect Kit
  • This product features Fluke Connect Technology

    See it. Save it. Share it. All the facts, right in the field.

    Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

    Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

    Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


    Fluke Connect Features:

    • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
    • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
    • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
    • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
    • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

    Fluke Connect Benefits:

    • Maximize uptime
    • Minimize maintenance costs
    • Better assessments with accurate records
    • Higher efficiency with less walking around; no notebook and excel needed
    • Share troubleshooting knowledge live
    • Create and share helpful content in the field
    • Access to Fluke digital product manuals means no need to carry manuals in the field
    • Keep organized manually entered measurements

    Click on a category to view a selection of compatible accessories with the Fluke Ti300 60hz FCA Fluke Connect Kit.

    Fluke LENS/25MAC2 Optional Thermal Imaging Lens, 25 µm Macro LENS/25MAC2
    Optional macro lens for the TI200/300/400 thermal imaging cameras.




    Fluke LENS/4XTELE2 Optional Thermal Imaging Lens, 4x Telephoto LENS/4XTELE2
    Optional 4X Telephoto Lens for the TI200/300/400 Thermal Imaging Cameras.




    Fluke FLK-050-CLKT C-Range IR Window 2" (50mm) FLK-050-CLKT
    2" (50mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-075-CLKT C-Range IR Window 3" (75mm) FLK-075-CLKT
    3" (75mm) C-Range IR Window for indoor and outdoor applications, with KWIK Twist Key that easily swivels off.




    Fluke FLK-100-CLKT C-Range IR Window 4" (100mm) FLK-100-CLKT
    C-Range IR Window for Outdoor and Indoor Applications, 4" (100m) with KWIK Twist.




    Fluke CV200 ClirVu 50 mm (2 in) Infrared Window, Hand Turn CV200
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV401 ClirVu 95 mm (4 in) Infrared Window, Security Key CV401
    Increase the safety and speed of your electrical thermal imaging inspection with the new Fluke CV Series of ClirVu infrared windows.




    Fluke CV400 ClirVu 95 mm (4 in) Infrared Window, Hand Turn CV400
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Fluke CV300 ClirVu 75 mm (3 in) Infrared Window, Hand Turn CV300
    Reduce the risk of arc-flash and electrocution, increase the safety of your personnel and reduce the time and cost of preventive maintenance.




    Ask a question about Fluke Ti300 60hz FCA Fluke Connect Kit

    Customer Reviews for the Fluke TI300 60HZ/FCA

    More Fluke Products


    Fluke Connect is the best way to stay in contact with your team without leaving the field.