This calibrator has superior accuracy and functionality in an economical benchtop package. Ideal for wide workload coverage applications such as instrument shops and laboratories. Considered to be the most accurate Fluke Calibration temperature calibrator, sourcing and measuring a complete range of RTDs, thermocouples, and thermistors.
This calibrator has superior accuracy and functionality in an economical benchtop package. Ideal for wide workload coverage applications such as instrument shops and laboratories. Considered to be the most accurate Fluke Calibration temperature calibrator, sourcing and measuring a complete range of RTDs, thermocouples, and thermistors.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
This temperature/pressure calibrator gives you a workhorse combination of high accuracy and broad functionality for temperature and pressure instrument calibration. Compact and economical, it has an interface for automated calibration, providing wide workload coverage in instrument shops and calibration labs, as well as in ATE applications.
Features
Settling Time | Less than 5 seconds |
Standard Interfaces | Standard RS-232; IEEE (GPIB) |
Temperature Performance | Operating: 0 to 50°C Calibration (tcal): 15 to 35°C Storage: -20 to 70°C |
Temperature Coefficient | Temperature coefficient for temperatures outside tcal + 5°C is 10 % of the 90 day specification per°C |
Relative Humidity | Operating: <80% to 30°C, <70% to 40°C, 40% to 50°C Storage: <95%, non-condensing |
Analog Low Isolation | 20V |
EMC | IEC 61326- 1/1997 (EMC) |
Line Power | Voltage (selectable): 100V/120V or 220V/240V Frequency: 47 to 63 Hz Voltage Variation: ±10% about line voltage setting |
Weight | 9 lbs (4 kg) |
Dimensions | 13.1 x 31.3 x 47.3 cm (5.25 x 12.5 x 18.6") |
Click on a category to view a selection of compatible accessories with the Fluke 525B/A0 120V Temperature/Pressure Calibrator.
Settling Time | Less than 5 seconds |
Standard Interfaces | Standard RS-232; IEEE (GPIB) |
Temperature Performance | Operating: 0 to 50°C Calibration (tcal): 15 to 35°C Storage: -20 to 70°C |
Temperature Coefficient | Temperature coefficient for temperatures outside tcal + 5°C is 10 % of the 90 day specification per°C |
Relative Humidity | Operating: <80% to 30°C, <70% to 40°C, 40% to 50°C Storage: <95%, non-condensing |
Analog Low Isolation | 20V |
EMC | IEC 61326- 1/1997 (EMC) |
Line Power | Voltage (selectable): 100V/120V or 220V/240V Frequency: 47 to 63 Hz Voltage Variation: ±10% about line voltage setting |
Weight | 9 lbs (4 kg) |
Dimensions | 13.1 x 31.3 x 47.3 cm (5.25 x 12.5 x 18.6") |
Click on a category to view a selection of compatible accessories with the Fluke 525B/A0 120V Temperature/Pressure Calibrator.