1-800-561-8187

information@ITM.com

Chat Live

Customer Reviews

Fluke 7526A-156 Precision Process Calibrator, 115V

Model: 7526A-156 | UPC: 95969643573

Fluke 7526A-156 Precision Process Calibrator, 115V-


Downloads: datasheet

Fluke 7526A-156 Precision Process Calibrator, 115V

Model: 7526A-156

Calibrate RTD and thermocouple readouts, pressure gauges, temperature transmitters, digital process simulators, data loggers, multimeters and more using this precision process calibrator.

Calibrate RTD and thermocouple readouts, pressure gauges, temperature transmitters, digital process simulators, data loggers, multimeters and more using this precision process calibrator.

Your Price $11234.00 CAD
Availability 2 to 3 Weeks
Quantity

Fluke 7526A-156 Offers

Less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators.

Features

  • Sources and measures DC voltage, current, resistance, RTDs and thermocouples
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Includes 24V DC transmitter loop power supply
  • Measures 4 to 20mA loop current
  • Includes automated switch-test function
  • Accepts ITS-90 coefficients for accurate SPRT measurements
  • Compatible with MET/CAL Calibration Software
  • Includes certificate of calibration traceable to national standards (optional A2LA accredited calibration available upon request)

Fluke 7526A-156 Specifications

Standard Interface RS-232, IEEE-488 (GPIB)
Temperature Performance Operating: 0 to 50°C
Calibration (tcal): 18 to 28°C
Storage: -20 to 70°C
Electromagnetic Compatibility CE: Conforms to EN61326 (operation in controlled EM environments)
Temperature Coefficient For temperatures outside tcal 5°C is 10% of the 90-day specification (or 1 year if applicable) per °C
Relative Humidity Operating:
<80% to 30°C
<70% to 40°C
<40% to 50°C
Altitude Operating: 9,800ft (3,000m) max
Non-operating: 40,000ft (12,200m) max
Safety EN/IEC 61010-1:2010 3rd Edition, UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12
Analog Low Isolation 20V
Line Power 120V~: 100 to 120V
240V~: 220 to 240V
Line Frequency 47 to 63Hz
Line Voltage Variation ±10% about setting
Power Consumption 15VA maximum
Dimensions Height: 5.75in (14.6cm)
Width: 17.5in (44.5cm)
Depth: 11.75in (29.8cm)
Weight (without options) 9.35lbs (4.24kg)
Click here for complete specifications on the Fluke 7526A-156

What's included with the Fluke 7526A-156

  • Calibration Report
  • User Manual CD
  • Getting Started Guide
  • Power Cord
  • Thermocouple Shorting Jumper
  • USB-to-Serial Adapter Cable

Click on a category to view a selection of compatible accessories with the Fluke 7526A-156 Precision Process Calibrator, 115V.

Fluke 7526A-CASE Carrying Case for 7526A Precision Process Calibrators 7526A-CASE
With a strong, lightweight resin shell, this carrying case helps keep your 7526A precision process calibrator safe. The telescoping handle and in-line wheels make transporting the case fast and easy.




Customer Reviews for the Fluke 7526A-156

Ask a question about Fluke 7526A-156 Precision Process Calibrator, 115V

Fluke 7526A-156 Offers

Less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators.

Features

  • Sources and measures DC voltage, current, resistance, RTDs and thermocouples
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Includes 24V DC transmitter loop power supply
  • Measures 4 to 20mA loop current
  • Includes automated switch-test function
  • Accepts ITS-90 coefficients for accurate SPRT measurements
  • Compatible with MET/CAL Calibration Software
  • Includes certificate of calibration traceable to national standards (optional A2LA accredited calibration available upon request)

Fluke 7526A-156 Specifications

Standard Interface RS-232, IEEE-488 (GPIB)
Temperature Performance Operating: 0 to 50°C
Calibration (tcal): 18 to 28°C
Storage: -20 to 70°C
Electromagnetic Compatibility CE: Conforms to EN61326 (operation in controlled EM environments)
Temperature Coefficient For temperatures outside tcal 5°C is 10% of the 90-day specification (or 1 year if applicable) per °C
Relative Humidity Operating:
<80% to 30°C
<70% to 40°C
<40% to 50°C
Altitude Operating: 9,800ft (3,000m) max
Non-operating: 40,000ft (12,200m) max
Safety EN/IEC 61010-1:2010 3rd Edition, UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12
Analog Low Isolation 20V
Line Power 120V~: 100 to 120V
240V~: 220 to 240V
Line Frequency 47 to 63Hz
Line Voltage Variation ±10% about setting
Power Consumption 15VA maximum
Dimensions Height: 5.75in (14.6cm)
Width: 17.5in (44.5cm)
Depth: 11.75in (29.8cm)
Weight (without options) 9.35lbs (4.24kg)
Click here for complete specifications on the Fluke 7526A-156

What's included with the Fluke 7526A-156

  • Calibration Report
  • User Manual CD
  • Getting Started Guide
  • Power Cord
  • Thermocouple Shorting Jumper
  • USB-to-Serial Adapter Cable

Click on a category to view a selection of compatible accessories with the Fluke 7526A-156 Precision Process Calibrator, 115V.

Fluke 7526A-CASE Carrying Case for 7526A Precision Process Calibrators 7526A-CASE
With a strong, lightweight resin shell, this carrying case helps keep your 7526A precision process calibrator safe. The telescoping handle and in-line wheels make transporting the case fast and easy.




Ask a question about Fluke 7526A-156 Precision Process Calibrator, 115V

Customer Reviews for the Fluke 7526A-156

More Fluke Products