Built for fast, live-system solar troubleshooting, this combines the Fluke 393 FC Solar Clamp Meter with CAT III 1500 V rated TLPV MC4 test leads for safe, reliable current, voltage, and DC power measurements on energized PV systems. This kit is ideal for technicians who want a clamp-first workflow in combiner boxes, strings, and field service applications.
Built for fast, live-system solar troubleshooting, this combines the Fluke 393 FC Solar Clamp Meter with CAT III 1500 V rated TLPV MC4 test leads for safe, reliable current, voltage, and DC power measurements on energized PV systems. This kit is ideal for technicians who want a clamp-first workflow in combiner boxes, strings, and field service applications.
The Fluke 393 FC Solar Clamp Meter and TLPV1 MC4 Test Leads Kit is an essential toolkit for professionals working in solar and DC environments. Designed for safety and versatility, this bundle provides reliable measurement solutions for installations and maintenance tasks.
393FC Solar Clamp Meter:
TLPV1 MC4 to 4mm Test Lead Set:
TLPV2 Solar Clamp Test Lead Set:
Applications
| General specifications (393 FC) | |
| Maximum voltage between any terminal and earth ground | 1000 V AC 1500 V DC |
| Batteries | 2 AA IEC LR6 alkaline |
| Display | Dual display with backlight |
| Automatic power off | 20 minutes |
| Electrical specifications (393 FC) | |
| Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 64°F to 82°F (18°C to 28°C), relative humidity at 0% to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). |
| Temperature coefficients | Add 0.1 x specified accuracy for each 1.8°F (1°C) >82°F (28°C) or <64°F (18°C) |
| AC current: jaw | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% + 5 digits (10 Hz to 100 Hz) Accuracy: 2.5% + 5 digits (100 Hz to 500 Hz) Crest Factor (50/60 Hz): 2.5 @ 600.0 A 3.0 @ 500.0 A 1.42 @ 999.9 A Add 2% for C.F. >2 |
| AC current: flexible current probe | Range: 999.9 A 2500 A Resolution: 0.1 A (≤999.9 A) 1 A (≤2500 A) Accuracy: 3% RD + 5 digits (10 Hz to 500 Hz) Crest Factor (50/60 Hz): 2.5 @ 1400 A 3.0 @ 1100 A 1.42 @ 2500 A Add 2% for C.F. >2 |
| Position sensitivity | Distance from Optimum - i2500-10 Flex: A: 0.5 in (12.7 mm), Error: ±0.5% B: 0.8 in (20.3 mm), Error: ±1.0% C: 1.4 in (35.6 mm), Error: ±2.0% Distance from Optimum - i2500-18 Flex: A: 1.4 in (35.6 mm), Error: ±0.5% B: 2.0 in (50.8 mm), Error: ±1.0% C: 2.5 in (63.5 mm), Error: ±2.0% Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. |
| DC current | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% RD + 5 digits When using the ZERO function to compensate for offsets. |
| AC voltage | Range: 600.0 V 1000 V Resolution: 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy: 1% RD + 5 digits (20 Hz to 500 Hz) |
| DC voltage | Range: 600.0 V 1500 V Resolution: 0.1 V (≤600.0 V) 1 V (≤1500 V) Accuracy: 1% RD + 5 digits |
| mV dc | Range: 500.0 mV Resolution: 0.1 mV Accuracy: 1% RD + 5 digits |
| Amps frequency: jaw | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A |
| Amps frequency: flexible current probe | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A |
| Voltage frequency | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 20 Hz, ≥5 V 20 Hz to 100 Hz, ≥5 V 100 Hz to 500 Hz, ≥10 V |
| DC power | Range: 600.0 kVA (600.0 V dc range) 1500 kVA (1500 V dc range) Resolution: 0.1 kVA 1 kVA Accuracy: 2% RD + 2.0 kVA 2% RD + 20 kVA |
| Resistance | Range: 600.0 Ω 6000 Ω 60.00 kΩ Resolution: 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 0.01 kΩ (≤60.00 kΩ) Accuracy: 1% RD + 5 digits |
| Capacitance | Range: 100.0 μF 1000 μF Resolution: 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy: 1% RD + 5 digits |
| Inrush trigger level | 5 A |
| Environmental specifications (393 FC) | |
| Operating temperature | 14°F to 122°F (-10°C to 50°C) |
| Storage temperature | -40°F to 140°F (-40°C to 60°C) |
| Operating humidity | Non-condensing (<50°F / <10°C) ≤90% RH at 50°F to 86°F (10°C to 30°C) ≤75% RH at 86°F to 104°F (30°C to 40°C) ≤45% RH at 104°F to 122°F (40°C to 50°C) |
| Operating altitude | 6562' (2000 m) |
| Storage altitude | 39370' (12000 m) |
| Electromagnetic Compatibility (EMC) (393 FC) | |
| International | IEC 61326-1: Portable, Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
| Korea (KCC) | Class A equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Safety (393 FC) | |
| General | IEC 61010-1, Pollution Degree 2 |
| Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V |
| Wireless radio (393 FC) | |
| Radio frequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE |
| Wireless radio frequency range | 2400 MHz to 2483.5 MHz |
| Output power | <100 mW |
| Mechanical specifications (393 FC) | |
| Jaw opening | 1.34" (34 mm) |
| Flexible current probe diameter | 0.30" (7.5 mm) |
| Flexible current probe cable length | 5.9' (1.8 m) |
| Dimensions | 11.06 x 3.31 x 1.93" (281 x 84 x 49 mm) |
| Weight | 1.15 lbs (520 g), with batteries |
| TLPV | |
| Voltage | Complies to IEC / EN 61010-031 CAT III 1500 V Do Not Disconnect Under Load Not Intended for Permanent Installation |
| Current | 30 A |
| Temperature | 41 to 86°F (5 to 30°C), < 80 % RH 88 to 104°F (31 to 40°C), < 50 % RH |
| General specifications (393 FC) | |
| Maximum voltage between any terminal and earth ground | 1000 V AC 1500 V DC |
| Batteries | 2 AA IEC LR6 alkaline |
| Display | Dual display with backlight |
| Automatic power off | 20 minutes |
| Electrical specifications (393 FC) | |
| Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 64°F to 82°F (18°C to 28°C), relative humidity at 0% to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). |
| Temperature coefficients | Add 0.1 x specified accuracy for each 1.8°F (1°C) >82°F (28°C) or <64°F (18°C) |
| AC current: jaw | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% + 5 digits (10 Hz to 100 Hz) Accuracy: 2.5% + 5 digits (100 Hz to 500 Hz) Crest Factor (50/60 Hz): 2.5 @ 600.0 A 3.0 @ 500.0 A 1.42 @ 999.9 A Add 2% for C.F. >2 |
| AC current: flexible current probe | Range: 999.9 A 2500 A Resolution: 0.1 A (≤999.9 A) 1 A (≤2500 A) Accuracy: 3% RD + 5 digits (10 Hz to 500 Hz) Crest Factor (50/60 Hz): 2.5 @ 1400 A 3.0 @ 1100 A 1.42 @ 2500 A Add 2% for C.F. >2 |
| Position sensitivity | Distance from Optimum - i2500-10 Flex: A: 0.5 in (12.7 mm), Error: ±0.5% B: 0.8 in (20.3 mm), Error: ±1.0% C: 1.4 in (35.6 mm), Error: ±2.0% Distance from Optimum - i2500-18 Flex: A: 1.4 in (35.6 mm), Error: ±0.5% B: 2.0 in (50.8 mm), Error: ±1.0% C: 2.5 in (63.5 mm), Error: ±2.0% Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. |
| DC current | Range: 999.9 A Resolution: 0.1 A Accuracy: 2% RD + 5 digits When using the ZERO function to compensate for offsets. |
| AC voltage | Range: 600.0 V 1000 V Resolution: 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy: 1% RD + 5 digits (20 Hz to 500 Hz) |
| DC voltage | Range: 600.0 V 1500 V Resolution: 0.1 V (≤600.0 V) 1 V (≤1500 V) Accuracy: 1% RD + 5 digits |
| mV dc | Range: 500.0 mV Resolution: 0.1 mV Accuracy: 1% RD + 5 digits |
| Amps frequency: jaw | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A |
| Amps frequency: flexible current probe | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A |
| Voltage frequency | Range: 5.0 Hz to 500.0 Hz Resolution: 0.1 Hz Accuracy: 0.5% RD + 5 digits Trigger level: 5 Hz to 20 Hz, ≥5 V 20 Hz to 100 Hz, ≥5 V 100 Hz to 500 Hz, ≥10 V |
| DC power | Range: 600.0 kVA (600.0 V dc range) 1500 kVA (1500 V dc range) Resolution: 0.1 kVA 1 kVA Accuracy: 2% RD + 2.0 kVA 2% RD + 20 kVA |
| Resistance | Range: 600.0 Ω 6000 Ω 60.00 kΩ Resolution: 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 0.01 kΩ (≤60.00 kΩ) Accuracy: 1% RD + 5 digits |
| Capacitance | Range: 100.0 μF 1000 μF Resolution: 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) Accuracy: 1% RD + 5 digits |
| Inrush trigger level | 5 A |
| Environmental specifications (393 FC) | |
| Operating temperature | 14°F to 122°F (-10°C to 50°C) |
| Storage temperature | -40°F to 140°F (-40°C to 60°C) |
| Operating humidity | Non-condensing (<50°F / <10°C) ≤90% RH at 50°F to 86°F (10°C to 30°C) ≤75% RH at 86°F to 104°F (30°C to 40°C) ≤45% RH at 104°F to 122°F (40°C to 50°C) |
| Operating altitude | 6562' (2000 m) |
| Storage altitude | 39370' (12000 m) |
| Electromagnetic Compatibility (EMC) (393 FC) | |
| International | IEC 61326-1: Portable, Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
| Korea (KCC) | Class A equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| Safety (393 FC) | |
| General | IEC 61010-1, Pollution Degree 2 |
| Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V |
| Wireless radio (393 FC) | |
| Radio frequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE |
| Wireless radio frequency range | 2400 MHz to 2483.5 MHz |
| Output power | <100 mW |
| Mechanical specifications (393 FC) | |
| Jaw opening | 1.34" (34 mm) |
| Flexible current probe diameter | 0.30" (7.5 mm) |
| Flexible current probe cable length | 5.9' (1.8 m) |
| Dimensions | 11.06 x 3.31 x 1.93" (281 x 84 x 49 mm) |
| Weight | 1.15 lbs (520 g), with batteries |
| TLPV | |
| Voltage | Complies to IEC / EN 61010-031 CAT III 1500 V Do Not Disconnect Under Load Not Intended for Permanent Installation |
| Current | 30 A |