Measure AC and DC current to 600 A with the fixed jaw clamp on this True RMS clamp meter. This unit also measures AC and DC voltage to 1000 V and resistance to 6000 Ω, and enables you to troubleshoot non-linear signals. Additionally, this unit is Fluke Connect compatible. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Measure AC and DC current to 600 A with the fixed jaw clamp on this True RMS clamp meter. This unit also measures AC and DC voltage to 1000 V and resistance to 6000 Ω, and enables you to troubleshoot non-linear signals. Additionally, this unit is Fluke Connect compatible. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
| AC Current via Jaw | |
| Range | 600 A |
| Resolution | 0.1 A |
| Accuracy | 2% ±5 digits (10 to 100 Hz) 2.5% ±5 digits (100 to 500 Hz) |
| Crest Factor (50/60 Hz) | 2.5 at 600 A Add 2% for C.F. >2 |
| DC Current | |
| Range | 600 A |
| Resolution | 0.1 A |
| Accuracy | 2% ±5 digits |
| AC Voltage | |
| Range | 1000 V |
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
| Accuracy | 1.5% ±5 digits (20 to 500 Hz) |
| DC Voltage | |
| Range | 1000 V |
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) |
| Accuracy | 1% ±5 digits |
| mV DC | |
| Range | 500.0 mV |
| Resolution | 0.1 mV |
| Accuracy | 1% ±5 digits |
| Resistance | |
| Range | 6000 Ω |
| Resolution | 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) |
| Accuracy | 1% ±5 digits |
| Capacitance | |
| Range | 1000 µF |
| Resolution | 0.1 µF (≤100 µF) 1 µF (≤1000 µF) |
| Accuracy | 1% ±4 digits |
| General Specifications | |
| Maximum Voltage Between any Terminal and Earth Ground | 1000 V |
| Batteries | 2 x AA, NEDA 15 A, IEC LR6 |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Storage Temperature | -40 to 140°F (-40 to 60°C) |
| Operating Humidity - Non-Condensing at 50°F (<10°C)</td> | ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C) |
| Operating Altitude | 9842.5' (3000 m) |
| Storage Altitude | 39,370.1' (12,000 m) |
| Jaw Opening | 1.33" (34 mm) |
| Dimensions | 9.8 x 3.3 x 1.8" (249 x 85 x 45 mm) |
| Weight | 0.87 lb (395 g) |
| Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V IEC 61010-2-033:CAT III 1000 V/CAT IV 600 V |
| IP Rating | IEC 60529: IP30, non-operating |
| Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE |
Click on a category to view a selection of compatible accessories with the Fluke 374 FC-NIST True RMS AC/DC Clamp Meter, .