Fluke 190-504/UN ScopeMeter Test Tool, 500MHz, 4 Channel

Model: 190-504/UN

This scopemeter delivers greater accuracy and clarity. Ideal test tool for plant maintenance engineers and technicians, designed to withstand harsh, dirty, and hazardous industrial conditions.

This scopemeter delivers greater accuracy and clarity. Ideal test tool for plant maintenance engineers and technicians, designed to withstand harsh, dirty, and hazardous industrial conditions.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Fluke 190-504-III Color ScopeMeter, 500 MHz, 4 channels-

Fluke 190-504-III Color ScopeMeter, 500 MHz, 4 channels

Model: 190-504-III

Effortlessly diagnose, view, and capture complex waveforms, induced noise, intermittent events, signal fluctuations, or drift with this high-performance portable oscilloscope. Rugged and easy to use, this oscilloscope features a bright color display, four channels, and a bandwidth of 500 MHz.


The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV/dt) and peaks of any reflections or transients.

Features

  • Four electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • Fast sampling rate, up to 5 GS/s with up to 200 ps resolution
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 999 Count digital multimeter
  • Four meter measurements via scope BNC inputs in four-channel models
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

Using Fluke Thermal Imaging to Troubleshoot Motors & Drives

Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.

In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.

Read the Article
Facilities Maintenance Challenges and the Fluke Solutions

Fluke 190-504/UN Specifications

Bandwidth 500 MHz
Number of Channels 4
Real-Time Sample Rate 5 GS/s
Inputs 4 x BNc input scope plus DMM input
Independently Floating Isolated Inputs Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Input Sensitivity 2 mV-100 V/div plus variable attenuation
Trigger Types Connect-and-View, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger Source 4 x BNC input
Glitch Capture 8 ns
Maximum Record Length ScopeRecord Mode: 30,000 pts per input
Scope Mode: 10,000 pts per input
Persistence Digital persistence giving analog oscilloscope-like waveform decay
Waveform Compare Waveform reference with automatic pass/fail testing

What's included with the Fluke 190-504/UN

  • ScopeMeter
  • Voltage Probe Set
  • Strap
  • Adapter
  • USB Cable with mini-B connector
  • Battery
  • Battery Charger/Adapter
  • Windows Software

Click on a category to view a selection of compatible accessories with the Fluke 190-504/UN ScopeMeter Test Tool, 500MHz, 4 Channel.

Fluke BC190/830 Power Adapter, Universal, 190 Series BC190/830
Universal, mains power adapter for use with Fluke 190 Series ScopeMeter Test Tool.




Fluke VPS421-G Voltage Probe Set, Grey VPS421-G
Ruggedized high working voltage probe set for 190 series scopemeter, 150 MHZ 100:1 2000V (1000V CAT III TO EARTH).




Fluke SKMD001/NON-US Service Kit SKMD001/NON-US
Service kit meter and drive applications for Fluke 190 Scopemeters.




Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 190-504/UN ScopeMeter Test Tool, 500MHz, 4 Channel

Customer Reviews for the Fluke 190-504/UN

The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV/dt) and peaks of any reflections or transients.

Features

  • Four electrically isolated inputs
  • CAT III 1000 V / CAT IV 600 V safety rated
  • Fast sampling rate, up to 5 GS/s with up to 200 ps resolution
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 999 Count digital multimeter
  • Four meter measurements via scope BNC inputs in four-channel models
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

Using Fluke Thermal Imaging to Troubleshoot Motors & Drives

Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.

In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.

Read the Article
Facilities Maintenance Challenges and the Fluke Solutions

Fluke 190-504/UN Specifications

Bandwidth 500 MHz
Number of Channels 4
Real-Time Sample Rate 5 GS/s
Inputs 4 x BNc input scope plus DMM input
Independently Floating Isolated Inputs Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Input Sensitivity 2 mV-100 V/div plus variable attenuation
Trigger Types Connect-and-View, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger Source 4 x BNC input
Glitch Capture 8 ns
Maximum Record Length ScopeRecord Mode: 30,000 pts per input
Scope Mode: 10,000 pts per input
Persistence Digital persistence giving analog oscilloscope-like waveform decay
Waveform Compare Waveform reference with automatic pass/fail testing

What's included with the Fluke 190-504/UN

  • ScopeMeter
  • Voltage Probe Set
  • Strap
  • Adapter
  • USB Cable with mini-B connector
  • Battery
  • Battery Charger/Adapter
  • Windows Software

Click on a category to view a selection of compatible accessories with the Fluke 190-504/UN ScopeMeter Test Tool, 500MHz, 4 Channel.

Fluke BC190/830 Power Adapter, Universal, 190 Series BC190/830
Universal, mains power adapter for use with Fluke 190 Series ScopeMeter Test Tool.




Fluke VPS421-G Voltage Probe Set, Grey VPS421-G
Ruggedized high working voltage probe set for 190 series scopemeter, 150 MHZ 100:1 2000V (1000V CAT III TO EARTH).




Fluke SKMD001/NON-US Service Kit SKMD001/NON-US
Service kit meter and drive applications for Fluke 190 Scopemeters.




Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 190-504/UN ScopeMeter Test Tool, 500MHz, 4 Channel

Customer Reviews for the Fluke 190-504/UN

More Fluke Products