1-800-561-8187

information@ITM.com

Customer Reviews

Fluke 975V AirMeter w/ Air Velocity Probe

Model: 975V | UPC: 095969353090

Fluke 975V AirMeter w/ Air Velocity Probe-


Downloads: datasheet manual

Fluke 975V AirMeter w/ Air Velocity Probe

Model: 975V

CO2, CO, temperature, humidity, air velocity, MIN/MAX/AVG, backlight, alarms, datalogging with software/USB w/ Air Velocity Probe.

CO2, CO, temperature, humidity, air velocity, MIN/MAX/AVG, backlight, alarms, datalogging with software/USB w/ Air Velocity Probe.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

REED R9905 Data Logging Indoor Air Quality Meter-

REED R9905 Data Logging Indoor Air Quality Meter

Model: R9905

Measures carbon dioxide (CO2), temperature, humidity and automatically calculates time-weighted average (TWA) and short-term exposure Limit (STEL).

The replacement product is only available on our affiliate ITM.com website. Don't worry your cart and information will be brought over.


Not what you're looking for? Let’s do a search and help you find what you need.


Recommended Accessories


Fluke 975V Offers

Features

  • Calculates volumetric flow rate, and actual/standard velocity
  • Datalogging and downloading software included: Manual
  • Stores over 12,700 data samples over a user selectable time base
  • Articulated probe versions available ("-A")
  • Shipped as a kit which includes thermo-anemometer; straight or articulated probe; 4 alkaline batteries; USB cable and downloading software; manual; hard carrying case and NIST calibration certificate

Temperature

  • Range: -20 °C to 50 °C (-5 °F to 122 °F)
  • Display resolution: 0.1 °C (0.1 °F)
  • Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C; ± 0.5 °C/± 1.00°F from 5 °C to 40 °C; ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity

  • Range: 10 % to 90 % RH, non-condensing
  • Display Resolution: 1%
  • Accuracy: ± 2 % RH (10 % RH to 90 % RH)

Air velocity

  • Range: 50.0 fpm to 3000 fpm; 0.25 m/sec to 15 m/sec
  • Display Resolution: 1 fpm (0.005m/sec)
  • Accuracy: ±4 % or 4 fpm*; ±4 % or 0.02 m/sec* whichever is greater; *Accuracy specification only valid for velocity readings above 50 fpm

C0

  • Range: 0 to 500 ppm
  • Display Resolution: 1 ppm
  • Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH

C02

  • Range: 0 to 5000 ppm
  • Display Resolution: 1 ppm
  • Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Fluke 975V Specifications

Measured specifications
Temperature
Range -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution 0.1 °C (0.1 °F)
Accuracy ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range 10 % to 90 % RH, non-condensing
Display Resolution 1%
Accuracy ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range 50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution 1 fpm (0.005m/sec)
Accuracy ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
CO2
Range 0 to 500 ppm
Display Resolution 1 ppm
Accuracy ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH

Calculated specifications
Dew point temperature
Range -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution 0.1 °C (0.1 °F)
Accuracy ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution 0.1 °C, (0.1 °F)
Accuracy ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution 0.001 M3/min, (1 cfm)
Accuracy N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range 0 to 100%
Display Resolution 0.1
% outside air (based on CO2)
Range 0 to 100 %
Display Resolution 0.1 % N/A

General specifications
Operating and storage temperature

-20 °C to 50 °C (-4 °F to 122 °F)
Humidity

10 % to 90 % (non-condensing)
Altitude

Up to 2000 m (6562 ft)
Shock and vibration

MIL-PRF-28800F: Class 2
Multi-language interface

English, French, Spanish, Portuguese and German
Battery

Rechargeable Li-Ion (primary), three-AA (backup)
Data logging

25,000 records (continuous), 99 records (discrete)
Warranty

Two-years

Click here for complete specifications on the Fluke 975V

What's included with the Fluke 975V

  • Fluke 975V AirMeter w/ Air Velocity Probe

Click on a category to view a selection of compatible accessories with the Fluke 975V AirMeter w/ Air Velocity Probe.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TPAK ToolPak Magnetic Meter Hanger ToolPak
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.




Ask a question about Fluke 975V AirMeter w/ Air Velocity Probe

Customer Reviews for the Fluke 975V

Fluke 975V Offers

Features

  • Calculates volumetric flow rate, and actual/standard velocity
  • Datalogging and downloading software included: Manual
  • Stores over 12,700 data samples over a user selectable time base
  • Articulated probe versions available ("-A")
  • Shipped as a kit which includes thermo-anemometer; straight or articulated probe; 4 alkaline batteries; USB cable and downloading software; manual; hard carrying case and NIST calibration certificate

Temperature

  • Range: -20 °C to 50 °C (-5 °F to 122 °F)
  • Display resolution: 0.1 °C (0.1 °F)
  • Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C; ± 0.5 °C/± 1.00°F from 5 °C to 40 °C; ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C

Relative humidity

  • Range: 10 % to 90 % RH, non-condensing
  • Display Resolution: 1%
  • Accuracy: ± 2 % RH (10 % RH to 90 % RH)

Air velocity

  • Range: 50.0 fpm to 3000 fpm; 0.25 m/sec to 15 m/sec
  • Display Resolution: 1 fpm (0.005m/sec)
  • Accuracy: ±4 % or 4 fpm*; ±4 % or 0.02 m/sec* whichever is greater; *Accuracy specification only valid for velocity readings above 50 fpm

C0

  • Range: 0 to 500 ppm
  • Display Resolution: 1 ppm
  • Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH

C02

  • Range: 0 to 5000 ppm
  • Display Resolution: 1 ppm
  • Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm

Fluke 975V Specifications

Measured specifications
Temperature
Range -20 °C to 50 °C (-5 °F to 122 °F)
Display resolution 0.1 °C (0.1 °F)
Accuracy ± 0.9 °C/± 1.62°F from 40 °C to 60 °C
± 0.5 °C/± 1.00°F from 5 °C to 40 °C
± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative humidity
Range 10 % to 90 % RH, non-condensing
Display Resolution 1%
Accuracy ± 2 % RH (10 % RH to 90 % RH)
Air velocity
Range 50.0 fpm to 3000 fpm
0.25 m/sec to 15 m/sec
Display Resolution 1 fpm (0.005m/sec)
Accuracy ±4 % or 4 fpm*
±4 % or 0.02 m/sec* whichever is greater
*Accuracy specification only valid for velocity readings above 50 fpm.
CO2
Range 0 to 500 ppm
Display Resolution 1 ppm
Accuracy ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and
50 % RH

Calculated specifications
Dew point temperature
Range -44 °C to 50 °C, (-47 °F to 122 °F)
Display Resolution 0.1 °C (0.1 °F)
Accuracy ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %
± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %
± 4 °C when RH: 10 % to 20 %
Wet bulb temperature
Range -16 °C to 50 °C, (3 °F to 122 °F)
Display Resolution 0.1 °C, (0.1 °F)
Accuracy ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C
± 2.1 °C when RH: 10 % to 20 %
Volume flow rate (in a duct)
Range 0 to 3,965 M3/m, (0 to 140,000 cfm)
Display Resolution 0.001 M3/min, (1 cfm)
Accuracy N/A: The volume flow calculation will be a simple average of the data points times the duct area
% outside air (based on temperature)
Range 0 to 100%
Display Resolution 0.1
% outside air (based on CO2)
Range 0 to 100 %
Display Resolution 0.1 % N/A

General specifications
Operating and storage temperature

-20 °C to 50 °C (-4 °F to 122 °F)
Humidity

10 % to 90 % (non-condensing)
Altitude

Up to 2000 m (6562 ft)
Shock and vibration

MIL-PRF-28800F: Class 2
Multi-language interface

English, French, Spanish, Portuguese and German
Battery

Rechargeable Li-Ion (primary), three-AA (backup)
Data logging

25,000 records (continuous), 99 records (discrete)
Warranty

Two-years

Click here for complete specifications on the Fluke 975V

What's included with the Fluke 975V

  • Fluke 975V AirMeter w/ Air Velocity Probe

Click on a category to view a selection of compatible accessories with the Fluke 975V AirMeter w/ Air Velocity Probe.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke TPAK ToolPak Magnetic Meter Hanger ToolPak
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.




Ask a question about Fluke 975V AirMeter w/ Air Velocity Probe

Customer Reviews for the Fluke 975V

More Fluke Products