Confidently take reliable readings with this clamp meter, and is for use with high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, and rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Confidently take reliable readings with this clamp meter, and is for use with high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, and rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Clamp Meters category for similar products.
Or let's do a search and help you find what you need:
Features
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22°C to 24°C Voltage: 0.1% of reading per °C outside 22°C to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Click on a category to view a selection of compatible accessories with the Fluke 353 True RMS Clamp Meter, 2000 A.
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22°C to 24°C Voltage: 0.1% of reading per °C outside 22°C to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Click on a category to view a selection of compatible accessories with the Fluke 353 True RMS Clamp Meter, 2000 A.