| Specifications |
| Voltage DC |
| Maximum Voltage | 1000 V | | Accuracy | ±(0.09%+2)) | | Maximum Resolution | 0.001V | |
| Maximum Voltage |
1000 V |
| Accuracy |
±(0.09%+2)) |
| Maximum Resolution |
0.001V |
| Voltage AC |
| Maximum Voltage | 1000 V | | Accuracy | ±(2%+3) | | AC Bandwidth | 5kHz* |
| *with low pass filter; 3db @ 800 Hz | | Maximum Resolution | 0.1 mV | |
| Maximum Voltage |
1000 V |
| Accuracy |
±(2%+3) |
| AC Bandwidth |
5kHz* |
| |
*with low pass filter; 3db @ 800 Hz |
| Maximum Resolution |
0.1 mV |
| Current DC |
| Maximum Amps | 400mA | | Amps Accuracy | ±(0.2%+2) | | Maximum Resolution | 0.01 mA | |
| Maximum Amps |
400mA |
| Amps Accuracy |
±(0.2%+2) |
| Maximum Resolution |
0.01 mA |
| Current AC |
| Maximum Amps | 400mA | | Amps Accuracy | | 1587: ±(1.5%+2)* | * 1kHz bandwidth | | | Maximum Resolution | 0.01 mA | |
| Maximum Amps |
400mA |
| Amps Accuracy |
| 1587: ±(1.5%+2)* | * 1kHz bandwidth |
|
| 1587: ±(1.5%+2)* |
* 1kHz bandwidth |
| Maximum Resolution |
0.01 mA |
| Resistance |
| Maximum Resistance | 50 MΩ | | Accuracy | ±(0.9%+2) | | Maximum Resolution | 0.1Ω | |
| Maximum Resistance |
50 MΩ |
| Accuracy |
±(0.9%+2) |
| Maximum Resolution |
0.1Ω |
| Capacitance |
| Maximum Capacitance | 9,999 μF | | Accuracy | ±(1.2%+2) | | Maximum Resolution | 1 nF | |
| Maximum Capacitance |
9,999 µF |
| Accuracy |
±(1.2%+2) |
| Maximum Resolution |
1 nF |
Frequency
|
| Maximum Frequency | 100 kHz | | Accuracy | ±(0.1%+1) | | Maximum Resolution | 0.01 Hz | |
| Maximum Frequency |
100 kHz |
| Accuracy |
±(0.1%+1) |
| Maximum Resolution |
0.01 Hz |
Temperature Measurement
|
| -40.0 to 537°C |
| -40.0 to 998°F |
| excluding probe | |
| |
-40.0 to 537°C |
| |
-40.0 to 998°F |
| |
excluding probe |
Diode Test
|
| Range | 6 V | | Resolution | 1 mV | | Accuracy | ±(2 % + 1) | |
| Range |
6 V |
| Resolution |
1 mV |
| Accuracy |
±(2 % + 1) |
| Insulation Test |
| Minimum Test Current @ 1kΩ/V |
|
| |
1mA |
| Test Voltages |
| 50, 100, 250, 500, 1000 V |
|
| Maximum Resistance per Test Voltage |
| 50V |
| | 100V |
| | 250V |
| | 500V |
| | 1000V | 2 GΩ | |
| 50V |
|
| 100V |
|
| 250V |
|
| 500V |
|
| 1000V |
2 GΩ |
| Maximum Resolution per Test Voltage |
| 50V | 0.01 MΩ | | 100V | 0.01 MΩ | | 250V | 0.1 MΩ | | 500V | 0.1 MΩ | | 1000V | 0.1 MΩ | |
| 50V |
0.01 MΩ |
| 100V |
0.01 MΩ |
| 250V |
0.1 MΩ |
| 500V |
0.1 MΩ |
| 1000V |
0.1 MΩ |
| Accuracy per Test Voltage |
|
| 50V |
±(3 % + 5) |
| 100V |
±(3 % + 5) |
| 250V |
±(1.5 % + 5) |
| 500V |
±(1.5 % + 5) |
| 1000V |
±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
| Environmental Specifications |
| Operating temperature |
|
| |
-20 to 55°C |
| Storage temperature |
|
| |
-40 to 60°C |
| Humidity (Without Condensation) |
| 0% - 95% (10°C - 30°C) |
| 0% - 75% (30°C - 40°C) |
| 0% - 40% (40°C - 55°C) | |
| |
0% - 95% (10°C - 30°C) |
| |
0% - 75% (30°C - 40°C) |
| |
0% - 40% (40°C - 55°C) |
| Operating Altitude |
|
| |
2000 m |
| Safety Specifications |
| Overvoltage category |
| Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
| |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
| Agency Approvals |
| 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
| |
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
| Mechanical & General Specifications |
| Size |
| 203 x 100 x 50 mm (with holster) |
|
| |
203 x 100 x 50 mm (with holster) |
| Weight |
|
| |
624 g |
| Warranty |
|
| |
3 years |
| Battery life Alkaline |
| Meter use | 1000 hours | | Insulation test use | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | |
| Meter use |
1000 hours |
| Insulation test use |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| IP Rating |
|
| |
IP40 |
| Specifications |
Temperature Range |
| Fluke 62 MAX | -30 to 500°C (-22 to 932°F) | | Fluke 62+ MAX | -30 to 650°C (-22 to 1202°F) | |
| Fluke 62 MAX |
-30 to 500°C (-22 to 932°F) |
| Fluke 62+ MAX |
-30 to 650°C (-22 to 1202°F) |
| Accuracy |
| Fluke 62 MAX | ±1.5°C or ±1.5% of reading, whichever is greater -10 to 0°C: ±2.0 -30 to -10°C: ±3.0 | | Fluke 62+ MAX | ±1.0°C or ±1.0% of reading, whichever is greater -10 to 0°C: ±2.0 -30 to -10°C: ±3.0 | |
| Fluke 62 MAX |
±1.5°C or ±1.5% of reading, whichever is greater -10 to 0°C: ±2.0 -30 to -10°C: ±3.0 |
| Fluke 62+ MAX |
±1.0°C or ±1.0% of reading, whichever is greater -10 to 0°C: ±2.0 -30 to -10°C: ±3.0 |
| Response Time (95%) |
| Fluke 62 MAX | <500 ms (95% of reading) | | Fluke 62+ MAX | <300 ms (95% of reading) | | Spectral Response | 8 to 14 microns | | Emissivity | 0.10 to 1.00 | |
| Fluke 62 MAX |
<500 ms (95% of reading) |
| Fluke 62+ MAX |
<300 ms (95% of reading) |
| Spectral Response |
8 to 14 microns |
| Emissivity |
0.10 to 1.00 |
Optical Resolution |
| Fluke 62 MAX | 10:1 (calculated at 90% energy) | | Fluke 62+ MAX | 12:1 (calculated at 90% energy) | |
| Fluke 62 MAX |
10:1 (calculated at 90% energy) |
| Fluke 62+ MAX |
12:1 (calculated at 90% energy) |
| Display Resolution |
|
| |
0.1°C (0.2°F) |
| Repeatability of Readings |
| Fluke 62 MAX | ±0.8% of reading or <±1.0°C (2°F), whichever is greater | | Fluke 62+ MAX | ±0.5% of reading or <±0.5°C (1°F), whichever is greater | |
| Fluke 62 MAX |
±0.8% of reading or <±1.0°C (2°F), whichever is greater |
| Fluke 62+ MAX |
±0.5% of reading or <±0.5°C (1°F), whichever is greater |
| Power |
|
| Battery Life |
| Fluke 62 MAX | 10 hours with laser and backlight on | | Fluke 62+ MAX | 8 hours with laser and backlight on | |
| Fluke 62 MAX |
10 hours with laser and backlight on |
| Fluke 62+ MAX |
8 hours with laser and backlight on |
Physical Specifications |
| Weight | 255 g (8.99 oz) | | Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | | Operating Temperature | 0 to 50°C (32 to 122°F) | | Storage Temperature | -20 to 60°C (-4 to 140°F), (without battery) | | Operating Humidity | 10 % to 90 % RH non-condensing at 30°C (86°F) | | Operating Altitude | 2000 meters above mean sea level | | Storage Altitude | 12,000 meters above mean sea level | | IP Rating | IP 54 per IEC 60529 | | Drop Test | 3 meters | | Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | | EMC | EN 61326-1:2006 EN 61326-2:2006 | |
| Weight |
255 g (8.99 oz) |
| Size |
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
| Operating Temperature |
0 to 50°C (32 to 122°F) |
| Storage Temperature |
-20 to 60°C (-4 to 140°F), (without battery) |
| Operating Humidity |
10 % to 90 % RH non-condensing at 30°C (86°F) |
| Operating Altitude |
2000 meters above mean sea level |
| Storage Altitude |
12,000 meters above mean sea level |
| IP Rating |
IP 54 per IEC 60529 |
| Drop Test |
3 meters |
| Vibration and Shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC |
EN 61326-1:2006 EN 61326-2:2006 |
Standards and Agency Approval |
| Compliance | EN/IEC 61010-1: 2001 | | Laser Safety | FDA and EN 60825-1 Class II | |
| Compliance |
EN/IEC 61010-1: 2001 |
| Laser Safety |
FDA and EN 60825-1 Class II |