Quickly and easily remove old fluids with this oil deadweighter tester's built-in drain plug. The tester has a measuring range from 200 to 20,000psi.
Quickly and easily remove old fluids with this oil deadweighter tester's built-in drain plug. The tester has a measuring range from 200 to 20,000psi.
This has mounted spirit level and adjustable feet.
Features
Standard Weight Material | Series 3 non-magnetic austenitic stainless steel |
Weight Density | 7.8g/cm3 |
Optional Fractional Weights | Solution heat-treated aluminum |
Piston Material | Tungsten carbide with nickel binder |
Density | 15g/cm3 |
Cylinder Material | Hardened martensitic steel; tungsten carbide (water above 500psi, 35bar) |
Thermal Coefficients of Expansion | Oil piston/cylinder: 16.5ppm/°C; water: (above 500psi, 35bar) 11ppm/°C |
Test Port Adapters | 1/8, 1/4, 3/8 and 1/2 NPT or BSP |
Reservoir Volume | 150cc |
Screw Press Displacement | 5.5cc |
Pump Displacement | 4.7cc per stroke |
O-Ring Seal Materials | Buna N as standard, Viton and EPDM available |
Click on a category to view a selection of compatible accessories with the Fluke P3116-PSI Oil Deadweight Tester, 200 to 20,000psi.
Standard Weight Material | Series 3 non-magnetic austenitic stainless steel |
Weight Density | 7.8g/cm3 |
Optional Fractional Weights | Solution heat-treated aluminum |
Piston Material | Tungsten carbide with nickel binder |
Density | 15g/cm3 |
Cylinder Material | Hardened martensitic steel; tungsten carbide (water above 500psi, 35bar) |
Thermal Coefficients of Expansion | Oil piston/cylinder: 16.5ppm/°C; water: (above 500psi, 35bar) 11ppm/°C |
Test Port Adapters | 1/8, 1/4, 3/8 and 1/2 NPT or BSP |
Reservoir Volume | 150cc |
Screw Press Displacement | 5.5cc |
Pump Displacement | 4.7cc per stroke |
O-Ring Seal Materials | Buna N as standard, Viton and EPDM available |