1-800-561-8187

information@ITM.com

Customer Reviews

Fluke 787B CAL Process Meter with calibration certificate, 1,000 V

Model: 787B CAL | UPC: 095969946865

Fluke 787B CAL Process Meter with calibration certificate, 1,000 V-


Downloads: datasheet manual

Fluke 787B CAL Process Meter with calibration certificate, 1,000 V

Model: 787B CAL

With a large, bright dual-measurement display, the Fluke 789 Cal Process Meter is a compact digital multimeter and mA loop calibrator solution that can quickly and easily troubleshoot every part of a control loop. It is full-featured mA loop calibrator with built-in 1000 V Loop Power.

With a large, bright dual-measurement display, the Fluke 789 Cal Process Meter is a compact digital multimeter and mA loop calibrator solution that can quickly and easily troubleshoot every part of a control loop. It is full-featured mA loop calibrator with built-in 1000 V Loop Power.

Your Price $2307.19 CAD
Availability 7 in Stock
Quantity

Fluke 787B CAL Offers

The Fluke 789B Process Meter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a full-featured loop calibrator with the power of a CAT III 1000 V, CAT IV 600 V safety rated digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a large, dual display with two levels of backlighting and externally accessible fuse and batteries for easy replacement. And its built-in, selectable 250-ohm HART® resistor eliminates the need to carry a separate resistor.

The 789 also has a built-in 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can also add the wireless data logging capabilities of the Fluke Connect™ mobile app to log data wirelessly to your smart phone and review it from a remote location.
*Requires Fluke IR3000FC module (not included). Not all models are available in all countries. Check with your local Fluke representative.

Features

  • 20 mA dc current source/measure/simulate
  • Simultaneous mA and % of scale readout
  • DMM designed to meet 1000 volt IEC 61010 CAT III and 600 V CAT IV standards
  • Fluke Connect® compatibility for wireless data logging (with IR3000FC module)*
  • Precision 1000 V, 440 mA true-rms digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes
  • Compact digital multimeter and mA loop calibrator solution
  • Full-featured mA loop calibrator with built-in 24 V Loop Power
  • Quickly and easily troubleshoot every part of a control loop
  • Large, bright dual-measurement display

Do a lot more while carrying a lot less

The 789 provides all standard DMM capabilities including frequency measurement to 20 kHz, Min/Max/Average/Hold/Relative modes, and diode test and continuity beeper. Combine that with the ability to troubleshoot every part of the loop.

Measure, source, simulate 4 to 20 mA signals, measure resistance, measure power, provide power to the loop and provide 250-ohm resistance to the loop. The 789 includes SpanCheck; 0% and 100% buttons to toggle between 4 and 20 mA sourcing, while the display can simultaneously show mA and% of scale readings for faster troubleshooting. It also delivers 1200-ohm drive capability on mA source.

Accuracy: This Process Meter offers manual step, 100%, 25%, Coarse, Fine, plus auto step and auto ramp. It also delivers 0.1% DC voltage accuracy and 0.05% DC current accuracy.

Applications

  • Electrical and Instrumentation professionals

Fluke 787B CAL Specifications

Measurement Function V DC
Range and resolution: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best accuracy (% of reading + LSD): 0.1% + 1

V AC (true-rms)
Range and resolution: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best accuracy (% of reading + LSD): 0.7% + 2

mA DC
Range and resolution: 30.000 mA
Best accuracy (% of reading + LSD): 0.05% + 2

A DC
Range and resolution: 1.000 A (0.440 A continuous)
Best accuracy (% of reading + LSD): 0.2% + 2

A AC
Range and resolution: 1.000 A (0.440 A continuous)
Best accuracy (% of reading + LSD): 1% + 2

Resistance
Range and resolution: 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Best accuracy (% of reading + LSD): 0.2% + 1

Frequency (0.5 Hz to 20 kHz)
Range and resolution: 199.99 Hz, 1999.9 Hz, 19.999 kHz
Best accuracy (% of reading + LSD): 0.005% + 1

Diode test
Range and resolution: 2.000 V (shows diode voltage drop)
Best accuracy (% of reading + LSD): 2% + 1

Continuity
Range and resolution: Beeps for resistance < approximately 100 ohms
Output Function DC current output (internal battery operation)
Range and resolution: 0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up), Over-range to 24.000 mA
Drive capability: 24 V compliance or 1200 ohms, at 20 mA
Accuracy (% of span): 0.05%

DC current simulate (Ext. 15 V to 48 V loop supply)
Range and resolution: 0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up), Over-range to 24.000 mA
Drive capability: 1000 ohms, at 20 mA
Accuracy (% of span): 0.05%

24 V loop supply*
Range and resolution: Minimum 24 V
Drive capability: 250 ohms at 20 mA
Accuracy (% of span): > 24 V

Current adjustment modes
Range and resolution: Manual: Coarse, Fine, 25% and 100% step
Drive capability: Automatic: Slow Ramp, Fast Ramp, 25% step

Temperature range of 64 to 82°F (18 to 28°C) for one year after calibration
Maximum voltage applied between any jack and earth ground 1000 V RMS
Vibration Random, 2 g, 5-500 Hz
Shock 3.28' (1 m) drop test
Safety IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V
Environmental Conditions Storage temperature: -40 to 140°F (-40 to 60°C)
Operating temperature: -4 to 131°F (-20 to 55°C)
Temperature coefficient: 0.05 x (specified accuracy) per °C (for temperatures < 64 °F or > 82 °F)
Relative humidity: 95% up to 86°F (30°C); 75% up to 104°F (40°C); 45% up to 122°F (50°C); 35% up to 131°F (55°C)
Power Battery: Four AA alkaline batteries
Battery life: 140 hours typical (measurement), 10 hours typical (sourcing 12 mA)
Dimensions 1.97 x 3.94 x 8" (50 x 100 x 203 mm)
Weight 1.3 lbs (600 g)
Click here for complete specifications on the Fluke 787B CAL

What's included with the Fluke 787B CAL

  • Process Meter
  • Alligator Clips
  • 4 x AA 1.5 V Alkaline Batteries (installed)
  • Safety-designed Test Lead Set

Click on a category to view a selection of compatible accessories with the Fluke 787B CAL Process Meter with calibration certificate, 1,000 V.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 787B CAL Process Meter with calibration certificate, 1,000 V

Customer Reviews for the Fluke 787B CAL

Fluke 787B CAL Offers

The Fluke 789B Process Meter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a full-featured loop calibrator with the power of a CAT III 1000 V, CAT IV 600 V safety rated digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a large, dual display with two levels of backlighting and externally accessible fuse and batteries for easy replacement. And its built-in, selectable 250-ohm HART® resistor eliminates the need to carry a separate resistor.

The 789 also has a built-in 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can also add the wireless data logging capabilities of the Fluke Connect™ mobile app to log data wirelessly to your smart phone and review it from a remote location.
*Requires Fluke IR3000FC module (not included). Not all models are available in all countries. Check with your local Fluke representative.

Features

  • 20 mA dc current source/measure/simulate
  • Simultaneous mA and % of scale readout
  • DMM designed to meet 1000 volt IEC 61010 CAT III and 600 V CAT IV standards
  • Fluke Connect® compatibility for wireless data logging (with IR3000FC module)*
  • Precision 1000 V, 440 mA true-rms digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes
  • Compact digital multimeter and mA loop calibrator solution
  • Full-featured mA loop calibrator with built-in 24 V Loop Power
  • Quickly and easily troubleshoot every part of a control loop
  • Large, bright dual-measurement display

Do a lot more while carrying a lot less

The 789 provides all standard DMM capabilities including frequency measurement to 20 kHz, Min/Max/Average/Hold/Relative modes, and diode test and continuity beeper. Combine that with the ability to troubleshoot every part of the loop.

Measure, source, simulate 4 to 20 mA signals, measure resistance, measure power, provide power to the loop and provide 250-ohm resistance to the loop. The 789 includes SpanCheck; 0% and 100% buttons to toggle between 4 and 20 mA sourcing, while the display can simultaneously show mA and% of scale readings for faster troubleshooting. It also delivers 1200-ohm drive capability on mA source.

Accuracy: This Process Meter offers manual step, 100%, 25%, Coarse, Fine, plus auto step and auto ramp. It also delivers 0.1% DC voltage accuracy and 0.05% DC current accuracy.

Applications

  • Electrical and Instrumentation professionals

Fluke 787B CAL Specifications

Measurement Function V DC
Range and resolution: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best accuracy (% of reading + LSD): 0.1% + 1

V AC (true-rms)
Range and resolution: 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
Best accuracy (% of reading + LSD): 0.7% + 2

mA DC
Range and resolution: 30.000 mA
Best accuracy (% of reading + LSD): 0.05% + 2

A DC
Range and resolution: 1.000 A (0.440 A continuous)
Best accuracy (% of reading + LSD): 0.2% + 2

A AC
Range and resolution: 1.000 A (0.440 A continuous)
Best accuracy (% of reading + LSD): 1% + 2

Resistance
Range and resolution: 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M
Best accuracy (% of reading + LSD): 0.2% + 1

Frequency (0.5 Hz to 20 kHz)
Range and resolution: 199.99 Hz, 1999.9 Hz, 19.999 kHz
Best accuracy (% of reading + LSD): 0.005% + 1

Diode test
Range and resolution: 2.000 V (shows diode voltage drop)
Best accuracy (% of reading + LSD): 2% + 1

Continuity
Range and resolution: Beeps for resistance < approximately 100 ohms
Output Function DC current output (internal battery operation)
Range and resolution: 0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up), Over-range to 24.000 mA
Drive capability: 24 V compliance or 1200 ohms, at 20 mA
Accuracy (% of span): 0.05%

DC current simulate (Ext. 15 V to 48 V loop supply)
Range and resolution: 0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up), Over-range to 24.000 mA
Drive capability: 1000 ohms, at 20 mA
Accuracy (% of span): 0.05%

24 V loop supply*
Range and resolution: Minimum 24 V
Drive capability: 250 ohms at 20 mA
Accuracy (% of span): > 24 V

Current adjustment modes
Range and resolution: Manual: Coarse, Fine, 25% and 100% step
Drive capability: Automatic: Slow Ramp, Fast Ramp, 25% step

Temperature range of 64 to 82°F (18 to 28°C) for one year after calibration
Maximum voltage applied between any jack and earth ground 1000 V RMS
Vibration Random, 2 g, 5-500 Hz
Shock 3.28' (1 m) drop test
Safety IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V
Environmental Conditions Storage temperature: -40 to 140°F (-40 to 60°C)
Operating temperature: -4 to 131°F (-20 to 55°C)
Temperature coefficient: 0.05 x (specified accuracy) per °C (for temperatures < 64 °F or > 82 °F)
Relative humidity: 95% up to 86°F (30°C); 75% up to 104°F (40°C); 45% up to 122°F (50°C); 35% up to 131°F (55°C)
Power Battery: Four AA alkaline batteries
Battery life: 140 hours typical (measurement), 10 hours typical (sourcing 12 mA)
Dimensions 1.97 x 3.94 x 8" (50 x 100 x 203 mm)
Weight 1.3 lbs (600 g)
Click here for complete specifications on the Fluke 787B CAL

What's included with the Fluke 787B CAL

  • Process Meter
  • Alligator Clips
  • 4 x AA 1.5 V Alkaline Batteries (installed)
  • Safety-designed Test Lead Set

Click on a category to view a selection of compatible accessories with the Fluke 787B CAL Process Meter with calibration certificate, 1,000 V.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 787B CAL Process Meter with calibration certificate, 1,000 V

Customer Reviews for the Fluke 787B CAL

More Fluke Products