Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options

Model: 5608-9-J | UPC: 95969421928

Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options-


Downloads: datasheet

Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options

Model: 5608-9-J

The 6ft lead and banana plugs on this secondary PRT expand its connectivity.

The 6ft lead and banana plugs on this secondary PRT expand its connectivity.

Sale Price $1001.70 CAD
Regular Price $1113.00 CAD
Availability 2 to 3 Weeks
Quantity

Fluke 5608-9-J Offers

This secondary PRT with calibration options has a dry-well reference with a 90° bend.

Features

  • -328 to 932°F (-200 to 500°C) (3.15in (80mm) minimum immersion)
  • ±0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

Fluke 5608-9-J Specifications

Temperature Range -328 to 932°F (-200 to 500°C)
Nominal Resistance at 0.01°C 100Ω ±0.5Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
Drift ±0.01 at 0.010°C; ±0.02°C at max temp
Hysteresis ±0.01°C maximum
Sensor Length 1.2in ±0.2in (30mm ±5mm)
Sensor Location 0.1in ± 0.1in (3mm ±1mm from tip)
Minimum Insulation Resistance 500MΩ at 23°C, 20MΩ at 500°C
Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
Minimum Immersion Length (<5 mK Error) 3.1in (80mm)
Maximum Immersion Length 12in (305mm)
Response Time 9 seconds typical
Self Heating (In 0°C Bath) 75mW/°C
Lead-Wire Cable Type Teflon, 24AWG
Lead-Wire Length 6ft (1.8m)
Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
Click here for complete specifications on the Fluke 5608-9-J

What's included with the Fluke 5608-9-J

  • Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options
  • Customer Reviews for the Fluke 5608-9-J

    Ask a question about Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options

    Fluke 5608-9-J Offers

    This secondary PRT with calibration options has a dry-well reference with a 90° bend.

    Features

    • -328 to 932°F (-200 to 500°C) (3.15in (80mm) minimum immersion)
    • ±0.01 short-term stability
    • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

    Fluke 5608-9-J Specifications

    Temperature Range -328 to 932°F (-200 to 500°C)
    Nominal Resistance at 0.01°C 100Ω ±0.5Ω
    Temperature Coefficient 0.0039250Ω/Ω/°C
    Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
    Drift ±0.01 at 0.010°C; ±0.02°C at max temp
    Hysteresis ±0.01°C maximum
    Sensor Length 1.2in ±0.2in (30mm ±5mm)
    Sensor Location 0.1in ± 0.1in (3mm ±1mm from tip)
    Minimum Insulation Resistance 500MΩ at 23°C, 20MΩ at 500°C
    Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
    Minimum Immersion Length (<5 mK Error) 3.1in (80mm)
    Maximum Immersion Length 12in (305mm)
    Response Time 9 seconds typical
    Self Heating (In 0°C Bath) 75mW/°C
    Lead-Wire Cable Type Teflon, 24AWG
    Lead-Wire Length 6ft (1.8m)
    Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
    Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
    Click here for complete specifications on the Fluke 5608-9-J

    What's included with the Fluke 5608-9-J

  • Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options
  • Ask a question about Fluke 5608-9-J Secondary PRT with Banana Plugs, -200 to 500°C, Calibration Options

    Customer Reviews for the Fluke 5608-9-J

    More Fluke Products