1-800-561-8187

information@ITM.com

Customer Reviews

Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Model: 5608-12-I | UPC: 095969421836

Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options-


Downloads: datasheet manual

Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Model: 5608-12-I

Featuring Inconel sheaths and INFO-CON connections, this secondary PRT works with 1521 and 1522 models and comes with calibration options.

Featuring Inconel sheaths and INFO-CON connections, this secondary PRT works with 1521 and 1522 models and comes with calibration options.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Fluke 5608-12-I Offers

Features

  • -328 to 932°F (-200 to 500°C) (3.15in (80mm) minimum immersion)
  • ±0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

Fluke 5608-12-I Specifications

Temperature Range -328 to 932°F (-200 to 500°C)
Nominal Resistance at 0.01°C 100Ω ±0.5Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
Drift ±0.01 at 0.010°C; ±0.02°C at max temp
Hysteresis ±0.01°C maximum
Sensor Length 1.2in ±0.2in (30mm ±5mm)
Sensor Location 0.1in ± 0.1in (3mm ±1mm from tip)
Minimum Insulation Resistance 500MΩ at 23°C, 20MΩ at 500°C
Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
Minimum Immersion Length (<5 mK Error) 3.1in (80mm)
Maximum Immersion Length 12in (305mm)
Response Time 9 seconds typical
Self Heating (In 0°C Bath) 75mW/°C
Lead-Wire Cable Type Teflon, 24AWG
Lead-Wire Length 6ft (1.8m)
Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
Click here for complete specifications on the Fluke 5608-12-I

What's included with the Fluke 5608-12-I

  • Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Click on a category to view a selection of compatible accessories with the Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Customer Reviews for the Fluke 5608-12-I

Fluke 5608-12-I Offers

Features

  • -328 to 932°F (-200 to 500°C) (3.15in (80mm) minimum immersion)
  • ±0.01 short-term stability
  • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0

Fluke 5608-12-I Specifications

Temperature Range -328 to 932°F (-200 to 500°C)
Nominal Resistance at 0.01°C 100Ω ±0.5Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Short-Term Repeatability ±0.01 at 0.010°C; ±0.02°C at max temp
Drift ±0.01 at 0.010°C; ±0.02°C at max temp
Hysteresis ±0.01°C maximum
Sensor Length 1.2in ±0.2in (30mm ±5mm)
Sensor Location 0.1in ± 0.1in (3mm ±1mm from tip)
Minimum Insulation Resistance 500MΩ at 23°C, 20MΩ at 500°C
Transition Junction Dimensions 2.8 x 0.49in (71 x 12.5mm)
Minimum Immersion Length (<5 mK Error) 3.1in (80mm)
Maximum Immersion Length 12in (305mm)
Response Time 9 seconds typical
Self Heating (In 0°C Bath) 75mW/°C
Lead-Wire Cable Type Teflon, 24AWG
Lead-Wire Length 6ft (1.8m)
Lead-Wire Temperature Range -58 to 482°F (-50 to 250°C)
Calibration Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties
Click here for complete specifications on the Fluke 5608-12-I

What's included with the Fluke 5608-12-I

  • Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Click on a category to view a selection of compatible accessories with the Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 5608-12-I Secondary PRT with INFO-CON for 1521/1522 Models, Calibration Options

Customer Reviews for the Fluke 5608-12-I

More Fluke Products