1-800-561-8187

information@ITM.com

Customer Reviews

Fluke 393FC-TLPV Solar Testing Kit with solar clamp meter

Model: 393FC-TLPV

Fluke 393FC-TLPV Solar Testing Kit with solar clamp meter-


Downloads: datasheet

Fluke 393FC-TLPV Solar Testing Kit with solar clamp meter

Model: 393FC-TLPV

Built for fast, live-system solar troubleshooting, this combines the Fluke 393 FC Solar Clamp Meter with CAT III 1500 V rated TLPV MC4 test leads for safe, reliable current, voltage, and DC power measurements on energized PV systems. This kit is ideal for technicians who want a clamp-first workflow in combiner boxes, strings, and field service applications.

Built for fast, live-system solar troubleshooting, this combines the Fluke 393 FC Solar Clamp Meter with CAT III 1500 V rated TLPV MC4 test leads for safe, reliable current, voltage, and DC power measurements on energized PV systems. This kit is ideal for technicians who want a clamp-first workflow in combiner boxes, strings, and field service applications.

Your Price $1602.89 CAD
Availability 2 to 3 Weeks
Quantity

Fluke 393FC-TLPV Offers

The Fluke 393 FC Solar Clamp Meter and TLPV1 MC4 Test Leads Kit is an essential toolkit for professionals working in solar and DC environments. Designed for safety and versatility, this bundle provides reliable measurement solutions for installations and maintenance tasks.

393FC Solar Clamp Meter:

  • DC power measurement, showing readings in kVA and audio polarity indicator helps prevent accidental miswires
  • CAT III 1500V rated for safe, high-voltage measurements
  • Thin jaw design for easy access to cables in crowded combiner boxes
  • iFlex flexible current probe extends AC current measurements up to 2500A and gives you unparalleled access to cables in tight spaces
  • IP54 rated, ideal for work outdoors on solar arrays and wind power systems
  • Logging and reporting of test results via Fluke Connect software

TLPV1 MC4 to 4mm Test Lead Set:

  • Facilitates connection of measuring devices to PV power plants, ideal for routine tests and troubleshooting on Staubli MC4-connected solar PV panels
  • Compatible with test tools accepting 4 mm sheathed banana plugs
  • Nickel plated contacts provide robust and reliable connections with minimal resistance and corrosion
  • 59" (150 cm) long test leads with color-coded black (female) and red (male) MC4 connectors for quick identification and usability

TLPV2 Solar Clamp Test Lead Set:

  • Black and red MC4 test leads for accurate solar DC measurements
  • Facilitates troubleshooting and maintenance of solar PV circuits
  • Nickel-plated contacts for long-lasting durability

Applications

  • Live PV system troubleshooting
  • Combiner box and string testing
  • Solar field service and maintenance

Fluke 393FC-TLPV Specifications

General specifications (393 FC)
Maximum voltage between any terminal and earth ground 1000 V AC
1500 V DC
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic power off 20 minutes
Electrical specifications (393 FC)
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 64°F to 82°F (18°C to 28°C), relative humidity at 0% to 75%.
Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature coefficients Add 0.1 x specified accuracy for each 1.8°F (1°C) >82°F (28°C) or <64°F (18°C)
AC current: jaw Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 Hz to 100 Hz)
Accuracy: 2.5% + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz): 2.5 @ 600.0 A
3.0 @ 500.0 A
1.42 @ 999.9 A
Add 2% for C.F. >2
AC current: flexible current probe Range: 999.9 A
2500 A
Resolution: 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy: 3% RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60 Hz): 2.5 @ 1400 A
3.0 @ 1100 A
1.42 @ 2500 A
Add 2% for C.F. >2
Position sensitivity Distance from Optimum - i2500-10 Flex:
A: 0.5 in (12.7 mm), Error: ±0.5%
B: 0.8 in (20.3 mm), Error: ±1.0%
C: 1.4 in (35.6 mm), Error: ±2.0%

Distance from Optimum - i2500-18 Flex:
A: 1.4 in (35.6 mm), Error: ±0.5%
B: 2.0 in (50.8 mm), Error: ±1.0%
C: 2.5 in (63.5 mm), Error: ±2.0%

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits
When using the ZERO function to compensate for offsets.
AC voltage Range: 600.0 V
1000 V
Resolution: 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 Hz to 500 Hz)
DC voltage Range: 600.0 V
1500 V
Resolution: 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV dc Range: 500.0 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps frequency: jaw Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps frequency: flexible current probe Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage frequency Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC power Range: 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution: 0.1 kVA
1 kVA
Accuracy: 2% RD + 2.0 kVA
2% RD + 20 kVA
Resistance Range: 600.0 Ω
6000 Ω
60.00 kΩ
Resolution: 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance Range: 100.0 μF
1000 μF
Resolution: 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level 5 A
Environmental specifications (393 FC)
Operating temperature 14°F to 122°F (-10°C to 50°C)
Storage temperature -40°F to 140°F (-40°C to 60°C)
Operating humidity Non-condensing (<50°F / <10°C)
≤90% RH at 50°F to 86°F (10°C to 30°C)
≤75% RH at 86°F to 104°F (30°C to 40°C)
≤45% RH at 104°F to 122°F (40°C to 50°C)
Operating altitude 6562' (2000 m)
Storage altitude 39370' (12000 m)
Electromagnetic Compatibility (EMC) (393 FC)
International IEC 61326-1: Portable, Electromagnetic Environment
IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it.
This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety (393 FC)
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless radio (393 FC)
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range 2400 MHz to 2483.5 MHz
Output power <100 mW
Mechanical specifications (393 FC)
Jaw opening 1.34" (34 mm)
Flexible current probe diameter 0.30" (7.5 mm)
Flexible current probe cable length 5.9' (1.8 m)
Dimensions 11.06 x 3.31 x 1.93" (281 x 84 x 49 mm)
Weight 1.15 lbs (520 g), with batteries
TLPV
Voltage Complies to IEC / EN 61010-031
CAT III 1500 V
Do Not Disconnect Under Load
Not Intended for Permanent Installation
Current 30 A
Temperature 41 to 86°F (5 to 30°C), < 80 % RH
88 to 104°F (31 to 40°C), < 50 % RH
Click here for complete specifications on the Fluke 393FC-TLPV

What's included with the Fluke 393FC-TLPV

  • 393 FC TRMS Clamp Meter
  • Test Leads with Safety Caps
  • iFlex 18" (457.2 mm) Fexible Current Probe
  • MC4 to 4mm Test Lead Set
  • Solar Clamp Test Lead Set
  • TLPV-UTOOL Solar PV Connector Unlocking Tool
  • LeadWrap
  • TPAK Magnetic Hanging Strap
  • Carrying Case

Ask a question about Fluke 393FC-TLPV Solar Testing Kit with solar clamp meter

Customer Reviews for the Fluke 393FC-TLPV

Fluke 393FC-TLPV Offers

The Fluke 393 FC Solar Clamp Meter and TLPV1 MC4 Test Leads Kit is an essential toolkit for professionals working in solar and DC environments. Designed for safety and versatility, this bundle provides reliable measurement solutions for installations and maintenance tasks.

393FC Solar Clamp Meter:

  • DC power measurement, showing readings in kVA and audio polarity indicator helps prevent accidental miswires
  • CAT III 1500V rated for safe, high-voltage measurements
  • Thin jaw design for easy access to cables in crowded combiner boxes
  • iFlex flexible current probe extends AC current measurements up to 2500A and gives you unparalleled access to cables in tight spaces
  • IP54 rated, ideal for work outdoors on solar arrays and wind power systems
  • Logging and reporting of test results via Fluke Connect software

TLPV1 MC4 to 4mm Test Lead Set:

  • Facilitates connection of measuring devices to PV power plants, ideal for routine tests and troubleshooting on Staubli MC4-connected solar PV panels
  • Compatible with test tools accepting 4 mm sheathed banana plugs
  • Nickel plated contacts provide robust and reliable connections with minimal resistance and corrosion
  • 59" (150 cm) long test leads with color-coded black (female) and red (male) MC4 connectors for quick identification and usability

TLPV2 Solar Clamp Test Lead Set:

  • Black and red MC4 test leads for accurate solar DC measurements
  • Facilitates troubleshooting and maintenance of solar PV circuits
  • Nickel-plated contacts for long-lasting durability

Applications

  • Live PV system troubleshooting
  • Combiner box and string testing
  • Solar field service and maintenance

Fluke 393FC-TLPV Specifications

General specifications (393 FC)
Maximum voltage between any terminal and earth ground 1000 V AC
1500 V DC
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic power off 20 minutes
Electrical specifications (393 FC)
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 64°F to 82°F (18°C to 28°C), relative humidity at 0% to 75%.
Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature coefficients Add 0.1 x specified accuracy for each 1.8°F (1°C) >82°F (28°C) or <64°F (18°C)
AC current: jaw Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 Hz to 100 Hz)
Accuracy: 2.5% + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz): 2.5 @ 600.0 A
3.0 @ 500.0 A
1.42 @ 999.9 A
Add 2% for C.F. >2
AC current: flexible current probe Range: 999.9 A
2500 A
Resolution: 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy: 3% RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60 Hz): 2.5 @ 1400 A
3.0 @ 1100 A
1.42 @ 2500 A
Add 2% for C.F. >2
Position sensitivity Distance from Optimum - i2500-10 Flex:
A: 0.5 in (12.7 mm), Error: ±0.5%
B: 0.8 in (20.3 mm), Error: ±1.0%
C: 1.4 in (35.6 mm), Error: ±2.0%

Distance from Optimum - i2500-18 Flex:
A: 1.4 in (35.6 mm), Error: ±0.5%
B: 2.0 in (50.8 mm), Error: ±1.0%
C: 2.5 in (63.5 mm), Error: ±2.0%

Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits
When using the ZERO function to compensate for offsets.
AC voltage Range: 600.0 V
1000 V
Resolution: 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 Hz to 500 Hz)
DC voltage Range: 600.0 V
1500 V
Resolution: 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV dc Range: 500.0 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps frequency: jaw Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps frequency: flexible current probe Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage frequency Range: 5.0 Hz to 500.0 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits
Trigger level: 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC power Range: 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution: 0.1 kVA
1 kVA
Accuracy: 2% RD + 2.0 kVA
2% RD + 20 kVA
Resistance Range: 600.0 Ω
6000 Ω
60.00 kΩ
Resolution: 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance Range: 100.0 μF
1000 μF
Resolution: 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level 5 A
Environmental specifications (393 FC)
Operating temperature 14°F to 122°F (-10°C to 50°C)
Storage temperature -40°F to 140°F (-40°C to 60°C)
Operating humidity Non-condensing (<50°F / <10°C)
≤90% RH at 50°F to 86°F (10°C to 30°C)
≤75% RH at 86°F to 104°F (30°C to 40°C)
≤45% RH at 104°F to 122°F (40°C to 50°C)
Operating altitude 6562' (2000 m)
Storage altitude 39370' (12000 m)
Electromagnetic Compatibility (EMC) (393 FC)
International IEC 61326-1: Portable, Electromagnetic Environment
IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it.
This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety (393 FC)
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless radio (393 FC)
Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range 2400 MHz to 2483.5 MHz
Output power <100 mW
Mechanical specifications (393 FC)
Jaw opening 1.34" (34 mm)
Flexible current probe diameter 0.30" (7.5 mm)
Flexible current probe cable length 5.9' (1.8 m)
Dimensions 11.06 x 3.31 x 1.93" (281 x 84 x 49 mm)
Weight 1.15 lbs (520 g), with batteries
TLPV
Voltage Complies to IEC / EN 61010-031
CAT III 1500 V
Do Not Disconnect Under Load
Not Intended for Permanent Installation
Current 30 A
Temperature 41 to 86°F (5 to 30°C), < 80 % RH
88 to 104°F (31 to 40°C), < 50 % RH
Click here for complete specifications on the Fluke 393FC-TLPV

What's included with the Fluke 393FC-TLPV

  • 393 FC TRMS Clamp Meter
  • Test Leads with Safety Caps
  • iFlex 18" (457.2 mm) Fexible Current Probe
  • MC4 to 4mm Test Lead Set
  • Solar Clamp Test Lead Set
  • TLPV-UTOOL Solar PV Connector Unlocking Tool
  • LeadWrap
  • TPAK Magnetic Hanging Strap
  • Carrying Case

Ask a question about Fluke 393FC-TLPV Solar Testing Kit with solar clamp meter

Customer Reviews for the Fluke 393FC-TLPV

More Fluke Products