1-800-561-8187

information@ITM.com

Chat Live

Customer Reviews

Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT

Model: 1524-P1-156 | UPC: 095969481984

Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT-


Downloads: manual

Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT

Model: 1524-P1-156

Featuring a real-time clock, this handheld thermometer readout stores up to 15,000 time- and date-stamped measurements.

Featuring a real-time clock, this handheld thermometer readout stores up to 15,000 time- and date-stamped measurements.

This product has been discontinued. Click here for the replacement model(s).


Fluke 1524-P1-156 Offers

This thermometer readout delivers exceptional accuracy, wide measurement range, logging and trending, all in a handheld tool you can take anywhere.

Features

  • 2 channels, memory for logging 15,000 measurements and real-time clock for time and date stamps
  • 3 sensor types: PRTs -328 to 1,832°F (-200° to 1000°C), thermocouples -328 to 4,199°F (-200° to 2315°C) and precision thermistors -58 to 302°F (-50° to 150°C)
  • Accuracy: PRTs: ±0.011°C; thermocouples: ±0.24°C for J, K, L and M; precision thermistors: ±0.002°C
  • Fast mode: PRTs: 0.45 seconds per sample; thermocouples: 0.3 seconds per sample; precision thermistors: 0.3 seconds per sample
  • Graphical display: 128 x 64 backlit LCD graphic display, plot and scale trends in real time and simultaneous dual-channel readings

Fluke 1524-P1-156 Specifications

Input Channels 2
Logging 15,000 time and date stamped; 25 readings with statistics
Sample Interval (Normal) 1 second
Sample Interval (Fast Mode) 0.3 seconds (see technical manual for details)
Sensor Types PRTs, RTDs, thermistors, thermocouples
Thermocouple Types C, E, J, K, L, M, N, T, U, B, R, S
Operating Temperature 14 to 140°F (-10 to 60°C) (best accuracy 55.4 to 91.4°F (13 to 33°C))
Power Requirements 3 AA alkaline batteries
Size 3.75 x 7.9 x 1.86in (96 x 200 x 47mm)
Environmental Conditions For Best Accuracy 55.4 to 91.4°F (13 to 33°C)
Millivolt Range And Accuracy -10 to 75mV ±(0.005% + 5µV)
Resistance Range And Accuracy 0 to 400Ω ±(0.004% + 0.002Ω); 200 to 50kΩ ±(0.01% + 0.5Ω); 50 to 500kΩ ±(0.03%)
Temperature Coefficient, Voltage (-10 to 13°C, +33 to 60°C) ±(0.001%/°C + 1µV/°C)
Temperature Coefficient, Resistance (-10 to 13°C, +33 to 60°C) 0.0008%/°C + 0.0004Ω (0 to 400Ω); 0.002%/°C + 0.1Ω (0 to 50kΩ); 0.06%/°C + 0.1Ω (50 to 500kΩ)
Excitation Current, Resistance 1mA (0 to 400Ω); 10µA (0 to 50kΩ); 2µA (50 to 500kΩ)

What's included with the Fluke 1524-P1-156

  • Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT
  • Customer Reviews for the Fluke 1524-P1-156

    Ask a question about Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT

    Fluke 1524-P1-156 Offers

    This thermometer readout delivers exceptional accuracy, wide measurement range, logging and trending, all in a handheld tool you can take anywhere.

    Features

    • 2 channels, memory for logging 15,000 measurements and real-time clock for time and date stamps
    • 3 sensor types: PRTs -328 to 1,832°F (-200° to 1000°C), thermocouples -328 to 4,199°F (-200° to 2315°C) and precision thermistors -58 to 302°F (-50° to 150°C)
    • Accuracy: PRTs: ±0.011°C; thermocouples: ±0.24°C for J, K, L and M; precision thermistors: ±0.002°C
    • Fast mode: PRTs: 0.45 seconds per sample; thermocouples: 0.3 seconds per sample; precision thermistors: 0.3 seconds per sample
    • Graphical display: 128 x 64 backlit LCD graphic display, plot and scale trends in real time and simultaneous dual-channel readings

    Fluke 1524-P1-156 Specifications

    Input Channels 2
    Logging 15,000 time and date stamped; 25 readings with statistics
    Sample Interval (Normal) 1 second
    Sample Interval (Fast Mode) 0.3 seconds (see technical manual for details)
    Sensor Types PRTs, RTDs, thermistors, thermocouples
    Thermocouple Types C, E, J, K, L, M, N, T, U, B, R, S
    Operating Temperature 14 to 140°F (-10 to 60°C) (best accuracy 55.4 to 91.4°F (13 to 33°C))
    Power Requirements 3 AA alkaline batteries
    Size 3.75 x 7.9 x 1.86in (96 x 200 x 47mm)
    Environmental Conditions For Best Accuracy 55.4 to 91.4°F (13 to 33°C)
    Millivolt Range And Accuracy -10 to 75mV ±(0.005% + 5µV)
    Resistance Range And Accuracy 0 to 400Ω ±(0.004% + 0.002Ω); 200 to 50kΩ ±(0.01% + 0.5Ω); 50 to 500kΩ ±(0.03%)
    Temperature Coefficient, Voltage (-10 to 13°C, +33 to 60°C) ±(0.001%/°C + 1µV/°C)
    Temperature Coefficient, Resistance (-10 to 13°C, +33 to 60°C) 0.0008%/°C + 0.0004Ω (0 to 400Ω); 0.002%/°C + 0.1Ω (0 to 50kΩ); 0.06%/°C + 0.1Ω (50 to 500kΩ)
    Excitation Current, Resistance 1mA (0 to 400Ω); 10µA (0 to 50kΩ); 2µA (50 to 500kΩ)

    What's included with the Fluke 1524-P1-156

  • Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT
  • Ask a question about Fluke 1524-P1-156 Handheld Thermometer Readout with 5627A PRT

    Customer Reviews for the Fluke 1524-P1-156

    More Fluke Products